Back to Search
Start Over
ANGULAR DEPENDENCE OF TRACK-ETCH DETECTOR HARZLAS TD-1.
- Source :
-
Radiation protection dosimetry [Radiat Prot Dosimetry] 2019 Dec 31; Vol. 186 (2-3), pp. 219-223. - Publication Year :
- 2019
-
Abstract
- Track-etched detectors are commonly used also for radiation monitoring onboard International Space Station. To be registered in track-etched detectors, the particle needs to meet several criteria-it must have linear energy transfer above the detection threshold and strike the detector's surface under an angle higher than the so-called critical angle. Linear energy transfer is then estimated from calibration curve from the etch rate ratio V that is calculated from parameters of individual tracks appearing on the detector's surface after chemical etching. It has been observed that V can depend on the incident angle and this dependence can vary for different detector materials, etching and evaluating conditions. To investigate angular dependence, detectors (Harzlas TD-1) were irradiated at HIMAC by several ions under angles from 0° to 90°. The correction accounting not only for critical angle but also for dependence of V on the incident angle is introduced and applied to spectra measured onboard International Space Station.<br /> (© The Author(s) 2019. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.)
Details
- Language :
- English
- ISSN :
- 1742-3406
- Volume :
- 186
- Issue :
- 2-3
- Database :
- MEDLINE
- Journal :
- Radiation protection dosimetry
- Publication Type :
- Academic Journal
- Accession number :
- 31702766
- Full Text :
- https://doi.org/10.1093/rpd/ncz206