Back to Search Start Over

Development and validation of an LC-MS/MS method for the quantitative analysis of the anti-influenza agent camphecene in rat plasma and its application to study the blood-to-plasma distribution of the agent.

Authors :
Okhina AA
Rogachev AD
Yarovaya OI
Khvostov MV
Tolstikova TG
Pokrovsky AG
Khazanov VA
Salakhutdinov NF
Source :
Journal of pharmaceutical and biomedical analysis [J Pharm Biomed Anal] 2020 Feb 20; Vol. 180, pp. 113039. Date of Electronic Publication: 2019 Dec 10.
Publication Year :
2020

Abstract

A method of quantitative determination of camphecene, a new anti-influenza agent, in rat blood plasma based on LC-MS/MS was developed, validated and used to study the distribution of the agent between blood cells and blood plasma. The method was validated according to FDA and EMA recommendations in terms of selectivity, linearity, accuracy, precision, recovery, stability and carry-over. Plasma samples were precipitated with methanol followed by the addition of a methanolic solution of 2-adamantylamine hydrochloride (internal standard). HPLC analysis was performed on a reversed-phase column; the total time of analysis was 11 min, including column equilibration. MS/MS detection was performed on a 3200 QTRAP triple quadrupole mass spectrometer in multiple reaction monitoring (MRM) mode. Transitions 196.4 → 122.2/153.3 and 152.2 → 93.1/107.2 were monitored for camphecene and the internal standard, respectively. The calibration curve was built in the concentration range of 10-5000 ng/ml. The intra-day and inter-day accuracy and precision, carry-over and recovery were within the acceptable limits. It was found that, after spiking blood with camphecene and separating plasma, the concentration of the substance in the latter was close to its initial concentration in the blood. This property of the substance may be useful for clinical trials of the agent. It has also been established that the process of camphecene distribution (adsorption) between blood cells and blood plasma is reversible, and the amount of adsorbed substance is linearly dependent on its initial concentration in the blood for a wide range of concentrations, temperatures and hematocrit values.<br />Competing Interests: Declaration of Competing Interest The authors declare no conflict of interests.<br /> (Copyright © 2019 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1873-264X
Volume :
180
Database :
MEDLINE
Journal :
Journal of pharmaceutical and biomedical analysis
Publication Type :
Academic Journal
Accession number :
31865208
Full Text :
https://doi.org/10.1016/j.jpba.2019.113039