Back to Search
Start Over
4D flow vs. 2D cardiac MRI for the evaluation of pulmonary regurgitation and ventricular volume in repaired tetralogy of Fallot: a retrospective case control study.
- Source :
-
The international journal of cardiovascular imaging [Int J Cardiovasc Imaging] 2020 Apr; Vol. 36 (4), pp. 657-669. Date of Electronic Publication: 2020 Jan 01. - Publication Year :
- 2020
-
Abstract
- Lengthy exams and breath-holding limit the use of pediatric cardiac MRI (CMR). 3D time-resolved flow MRI (4DF) is a free-breathing, single-sequence exam that obtains magnitude (anatomic) and phase contrast (PC) data. We compare the accuracy of gadobenate dimeglumine-enhanced 4DF on a 1.5 T magnet to 2D CMR in children with repaired tetralogy of Fallot (rTOF) to measure pulmonary net flow (PNF) as a reflection of pulmonary regurgitation, forward flow (FF) and ventricular volumetry. Thirty-four consecutive cases were included. 2D PCs were obtained at the valve level. Using 4DF, we measured PNF at the valve and at the main and branch pulmonary arteries. PNF measured at the valve by 4DF demonstrated the strongest correlation (r = 0.87, p < 0.001) and lowest mean difference (3.5 ± 9.4 mL/beat) to aortic net flow (ANF). Semilunar FF and stroke volume of the respective ventricle demonstrated moderate-strong correlation by 4DF (r = 0.66-0.81, p < 0.001) and strong correlation by 2D (r = 0.81-0.84, p < 0.001) with similar correlations and mean differences between techniques (p > 0.05). Ventricular volumes correlated strongly between 2D and 4DF (r = 0.75-0.96, p < 0.001), though 4DF overestimated right ventricle volumes by 11.8-19.2 mL/beat. Inter-rater reliability was excellent for 2D and 4DF volumetry (ICC = 0.91-0.99). Ejection fraction moderately correlated (r = 0.60-0.75, p < 0.001) with better reliability by 4DF (ICC: 0.80-0.85) than 2D (ICC: 0.69-0.89). 4DF exams were shorter than 2D (9 vs. 71 min, p < 0.001). 4DF provides highly reproducible and accurate measurements of flow with slight overestimation of RV volumes compared to 2D in pediatric rTOF. 4DF offers important advantages in this population with long-term monitoring needs.
- Subjects :
- Adolescent
Blood Flow Velocity
Child
Contrast Media administration & dosage
Female
Humans
Male
Meglumine administration & dosage
Meglumine analogs & derivatives
Observer Variation
Organometallic Compounds administration & dosage
Predictive Value of Tests
Pulmonary Valve physiopathology
Pulmonary Valve Insufficiency etiology
Pulmonary Valve Insufficiency physiopathology
Reproducibility of Results
Retrospective Studies
Tetralogy of Fallot physiopathology
Treatment Outcome
Young Adult
Cardiac Surgical Procedures adverse effects
Echocardiography, Four-Dimensional
Magnetic Resonance Imaging
Pulmonary Valve diagnostic imaging
Pulmonary Valve Insufficiency diagnostic imaging
Stroke Volume
Tetralogy of Fallot surgery
Ventricular Function, Left
Ventricular Function, Right
Subjects
Details
- Language :
- English
- ISSN :
- 1875-8312
- Volume :
- 36
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- The international journal of cardiovascular imaging
- Publication Type :
- Academic Journal
- Accession number :
- 31894524
- Full Text :
- https://doi.org/10.1007/s10554-019-01751-1