Back to Search
Start Over
Repeated false reactive ADVIA centaur® and bio-rad Geenius™ HIV tests in a patient self-administering anabolic steroids.
- Source :
-
BMC infectious diseases [BMC Infect Dis] 2020 Jan 06; Vol. 20 (1), pp. 9. Date of Electronic Publication: 2020 Jan 06. - Publication Year :
- 2020
-
Abstract
- Background: An individual is considered HIV positive when a confirmatory HIV-1/HIV-2 differentiation test returns positive following an initial reactive antigen/antibody combination screen. Falsely reactive HIV screens have been reported in patients with various concomitant infectious and autoimmune conditions. Falsely positive confirmatory HIV differentiation assays are seen less frequently, but have been observed in cases of pregnancy, pulmonary embolism, and malaria.<br />Case Presentation: A healthy 27 year-old man was referred after a reactive ADVIA Centaur® HIV Ag/Ab screen and positive Bio-Rad Geenius™ HIV 1/2 Confirmatory assay, suggesting HIV-1 infection. The patient's HIV viral load was undetectable prior to initiation of antiretroviral therapy, and remained undetectable on subsequent testing after initiation of antiretroviral therapy. Both Centaur® and Geenius™ tests were repeated and returned reactive. As this patient was believed to be at low risk of acquiring HIV infection, samples were additionally run on Genscreen™ HIV-1 Ag assay and Fujirebio Inno-LIA™ HIV-1/2 score, with both returning non-reactive. For confirmation, the patient's proviral HIV DNA testing was negative, confirming the initial results as being falsely positive. The patient disclosed that he had been using a variety of anabolic steroids before and during the time of HIV testing.<br />Discussion and Conclusions: The erroneous diagnosis of HIV can result in decreased quality of life and adverse effects of antiretroviral therapy if initiated, hence the importance of interpreting the results of HIV testing in the context of an individual patient. This reports suggests a potential association between the use of anabolic steroids and falsely-reactive HIV testing.
- Subjects :
- Adult
HIV Antibodies blood
HIV Infections blood
HIV Infections virology
Humans
Male
Self Administration
Testosterone Congeners administration & dosage
Testosterone Congeners immunology
AIDS Serodiagnosis standards
False Positive Reactions
HIV immunology
HIV Infections diagnosis
Testosterone Congeners adverse effects
Subjects
Details
- Language :
- English
- ISSN :
- 1471-2334
- Volume :
- 20
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- BMC infectious diseases
- Publication Type :
- Academic Journal
- Accession number :
- 31906866
- Full Text :
- https://doi.org/10.1186/s12879-019-4722-8