Back to Search Start Over

Evaluating the Decision for Cochlear Implantation in Individuals With Single-Sided Deafness (SSD); Implementing the SSD Consensus Protocol Into Clinical Routine.

Authors :
Kurz A
Rak K
Hagen R
Ehrmann-Müller D
Source :
Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology [Otol Neurotol] 2020 Jul; Vol. 41 (6), pp. 727-735.
Publication Year :
2020

Abstract

Objective: To implement a unified testing framework into clinical routine that can be used by adults with single-sided deafness (SSD) to assess alternative treatment options before cochlear implantation.<br />Study Design: Retrospective data analysis.<br />Setting: Tertiary referral center with a large CI program.<br />Subjects and Methods: Thirty four participants underwent the new implemented testing procedure, including a test trial with contralateral routing of the signal (CROS) hearing aids and bone conduction devices (BCD) on a headband, before deciding whether to proceed with cochlear implantation. A test battery was used to assess speech in noise, binaural effects (head shadow, squelch, summation, spatial release from masking), sound localization, and quality of life. For participants that chose a CI, the same test battery was repeated during the 6 and 12 months follow-up appointments.<br />Results: Of the 34 participants involved in the study, 11 were implanted with a CI and finished their 12 month evaluation. Sixteen participants decided to stop after the CROS/BCD trial. In the CI-recipient group, a significant head shadow effect of 5.1 to 7.1 dB was achieved with the CI. Recipients in this group received only a limited benefit with either CROS or BCD before implantation. In the non-CI-recipient group, a significant difference between the CROS and BCD, in favor for the CROS device, was found calculating the head shadow and squelch effect. Localization abilities with the CI improved significantly in the CI-recipient group, even between the 6- and 12-month follow-up appointments. In the non-CI-recipient group, localization was significantly better with the BCD during the trial period. Higher scores were obtained from the speech and spatial categories of the Speech, Spatial, and Qualities of Hearing (SSQ) questionnaire with the CI. No subjective difference could be determined in the non-CI-recipient group.<br />Conclusion: Implementing the unified testing framework into a clinical routine was challenging but provided helpful insight into the best treatment option for each individual.

Details

Language :
English
ISSN :
1537-4505
Volume :
41
Issue :
6
Database :
MEDLINE
Journal :
Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology
Publication Type :
Academic Journal
Accession number :
32068694
Full Text :
https://doi.org/10.1097/MAO.0000000000002618