Back to Search Start Over

Bone formation around two titanium implant surfaces placed in bone defects with and without a bone substitute material: A histological, histomorphometric, and micro-computed tomography evaluation.

Authors :
Trento G
de A Carvalho PH
de C Reis ENR
Spin-Neto R
Bassi APF
Pereira-Filho VA
Source :
Clinical implant dentistry and related research [Clin Implant Dent Relat Res] 2020 Apr; Vol. 22 (2), pp. 177-185. Date of Electronic Publication: 2020 Feb 23.
Publication Year :
2020

Abstract

Objective: To evaluate the histological and microtomographic response of peri-implant bone tissue around titanium implants with different surface treatments, placed in bone defects filled or not filled with bone substitute materials.<br />Materials and Methods: Thirty rabbits were divided into two groups according to the implant surface treatment. A bone defect was created in both tibias of all the rabbits, followed by the placement of one implant in each of these defects. On the left tibia, the defect was filled with a blood clot (BC), and on the right tibia, the defect was filled with biphasic hydroxyapatite/β-tricalcium-phosphate (HA/TCP); thus, there were four groups in total: BC-N: bone defect filled with a BC and porous surface titanium implant (control group); BC-A: bone defect filled with a BC and porous-hydrophilic surface titanium implant; HA/TCP-N: bone defect filled with a bone substitute material and porous surface titanium implant; HA/TCP-A: bone defect filled with a bone substitute material and porous-hydrophilic surface titanium implant. The animals were submitted for euthanasia at three distinct periods: 15, 30, and 60 days after implant installation. The samples were evaluated histologically and histometrically, to assess the quantity and quality of cells and the remaining bone substitute material in the grafted areas. The bone quantity was assessed by micro-computed tomography (CT).<br />Results: For both surface types, the presence of a bone substitute material led to higher values in all evaluated micro-CT parameters, except in the bone surface/volume ratio parameter. No significant statistical difference was found for new bone formation between the four groups (P < .05; CI 95%). At all periods, the HA/TCP-A group had a higher percentage of new bone formation.<br />Conclusion: These results suggest that a porous hydrophilic surface in the presence of bone substitute material can accelerate peri-implant bone tissue formation.<br /> (© 2020 Wiley Periodicals, Inc.)

Details

Language :
English
ISSN :
1708-8208
Volume :
22
Issue :
2
Database :
MEDLINE
Journal :
Clinical implant dentistry and related research
Publication Type :
Academic Journal
Accession number :
32090450
Full Text :
https://doi.org/10.1111/cid.12880