Back to Search
Start Over
Performance evaluation of a laboratory developed PCR test for quantitation of HIV-2 viral RNA.
- Source :
-
PloS one [PLoS One] 2020 Feb 28; Vol. 15 (2), pp. e0229424. Date of Electronic Publication: 2020 Feb 28 (Print Publication: 2020). - Publication Year :
- 2020
-
Abstract
- Management of Human Immunodeficiency Virus Type 2 (HIV-2) infections present unique challenges due to low viral titers, slow disease progression, and poor response to standard antiviral therapies. The need for a nucleic acid assay to detect and quantify HIV-2 virus has led to the development of a number of molecular-based assays for detection and/or quantification of HIV-2 viral RNA in plasma in order to provide laboratory evidence of HIV-2 infection and viral loads for use in treatment decisions. As HIV-2 is less pathogenic and transmissible than HIV-1 and has resistance to several of the antiretroviral drugs, delay of treatment is common. Cross sero-reactivity between HIV-1 and HIV-2 makes it difficult to distinguish between the two viruses based upon serological tests. As such we developed a quantitative reverse transcription PCR (qRT-PCR) assay targeting the 5' long terminal repeat of HIV-2 for detection and quantification of HIV-2 viral RNA in plasma to identify HIV-2 infection and for use in viral load monitoring. Serial dilutions of cultured HIV-2 virus demonstrated a wide dynamic range (10 to 100,000 copies/ml) with excellent reproducibility (standard deviation from 0.12-0.19), linearity (R2 = 0.9994), and a lower limit of detection at 79 copies/ml (NIH-Z). The assay is highly specific for HIV-2 Groups A and B and exhibits no cross reactivity to HIV-1, HBV or HCV. Precision of the assay was demonstrated for the High (Mean = 6.41; SD = 0.12) and Medium (Mean = 4.46; SD = 0.13) HIV-2 positive controls. Replicate testing of clinical specimens showed good reproducibility above 1,000 copies/ml, with higher variability under 1,000 copies/ml. Analysis of 220 plasma samples from HIV-2 infected West African individuals demonstrated significantly lower viral loads than those observed in HIV-1 infections, consistent with results of previous studies. Slightly more than seven percent of clinical samples (7.3%) demonstrated viral loads above 100,000 copies/ml, while 37.3% of samples were undetectable. The high sensitivity, specificity, precision, and linearity of the WRAIR qRT-PCR assay makes it well suited for detection and monitoring of HIV-2 RNA levels in plasma of infected individuals.<br />Competing Interests: The authors have declared that no competing interests exist.
- Subjects :
- Case-Control Studies
HIV Infections blood
HIV Infections virology
HIV-1 isolation & purification
HIV-2 isolation & purification
Humans
RNA, Viral blood
Reagent Kits, Diagnostic
Viral Load
HIV Infections diagnosis
HIV-1 genetics
HIV-2 genetics
Laboratories standards
RNA, Viral genetics
Real-Time Polymerase Chain Reaction methods
Serologic Tests standards
Subjects
Details
- Language :
- English
- ISSN :
- 1932-6203
- Volume :
- 15
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- PloS one
- Publication Type :
- Academic Journal
- Accession number :
- 32109949
- Full Text :
- https://doi.org/10.1371/journal.pone.0229424