Comparison of acute thrombogenicity and albumin adsorption in three different durable polymer coronary drug-eluting stents.

Authors :
Jinnouchi H
Kutyna M
Torii S
Cheng Q
Sakamoto A
Guo L
Cornelissen A
Perkins LEL
Hossainy SF
Pacetti SD
Kolodgie FD
Virmani R
Finn AV
Source :
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology [EuroIntervention] 2021 Jun 25; Vol. 17 (3), pp. 248-256.
Publication Year :
2021

Abstract

Background: The relative thrombogenicity and albumin adsorption and retention of different durable polymers used in coronary stents has not been tested.<br />Aims: This study sought to compare the thromboresistance and albumin binding capacity of different durable polymer drug-eluting stents (DES) using dedicated preclinical and in vitro models.<br />Methods: In an ex vivo swine arteriovenous shunt model, a fluoropolymer everolimus-eluting stent (FP-EES) (n=14) was compared with two durable polymer DES, the BioLinx polymer-coated zotarolimus-eluting stent (BL-ZES) (n=9) and a CarboSil elastomer polymer-coated ridaforolimus-eluting stent (EP-RES) (n=6), and bare metal stents (BMS) (n=10). Stents underwent immunostaining using a cocktail of antiplatelet antibodies and a marker for inflammation and were then evaluated by confocal microscopy (CM). Albumin retention was assessed using a flow loop model with labelled human serum albumin (FP-EES [n=8], BL-ZES [n=4], EP-RES [n=4], and BMS [n=7]), and scanned by CM.<br />Results: The area of platelet adherence (normalised to total stent surface area) was lower in the order FP-EES (9.8%), BL-ZES (32.7%), EP-RES (87.6%) and BMS (202.0%), and inflammatory cell density was least for FP-EES <BL-ZES <EP-RES <BMS. Although nearly full coverage by albumin binding was shown for all durable polymer DES, FP-EES showed significantly greater intensity of albumin as compared to BL-ZES, EP-RES and BMS (FP-EES 79.0%; BL-ZES 13.2%; EP-RES 6.1%; BMS 1.5%).<br />Conclusions: These results suggest that thromboresistance and albumin retention vary by polymer type and that these differences might result in different suitability for short-term dual antiplatelet therapy.

Details

Language :
English
ISSN :
1969-6213
Volume :
17
Issue :
3
Database :
MEDLINE
Journal :
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology
Publication Type :
Academic Journal
Accession number :
32149708
Full Text :
https://doi.org/10.4244/EIJ-D-19-00938