Back to Search Start Over

Six-year multicenter study on short-term peripheral venous catheters-related bloodstream infection rates in 727 intensive care units of 268 hospitals in 141 cities of 42 countries of Africa, the Americas, Eastern Mediterranean, Europe, South East Asia, and Western Pacific Regions: International Nosocomial Infection Control Consortium (INICC) findings.

Authors :
Rosenthal VD
Bat-Erdene I
Gupta D
Belkebir S
Rajhans P
Zand F
Myatra SN
Afeef M
Tanzi VL
Muralidharan S
Al-Abdely HM
El-Kholy A
AlKhawaja SAA
Demiroz AP
Mehta Y
Rai V
Hung NV
Sayed AF
Salgado-Yepez E
Elahi N
Del Rayo Morfin-Otero M
Luxsuwong M
De-Carvalho BM
Tapang ARD
Velinova VA
Quesada-Mora AM
Anguseva T
Ikram A
Aguilar-de-Moros D
Duszynska W
Mejia N
Horhat FG
Belskiy V
Mioljevic V
Di-Silvestre G
Furova K
Gamar-Elanbya MO
Gupta U
Abidi K
Raka L
Guo X
Jayatilleke K
Ben-Jaballah N
Sandoval-Castillo HR
Trotter A
Valderrama-Beltrán SL
Leblebicioglu H
Guanche-Garcell H
de Lourdes-Dueñas M
Source :
Infection control and hospital epidemiology [Infect Control Hosp Epidemiol] 2020 May; Vol. 41 (5), pp. 553-563. Date of Electronic Publication: 2020 Mar 18.
Publication Year :
2020

Abstract

Background: Short-term peripheral venous catheter-related bloodstream infection (PVCR-BSI) rates have not been systematically studied in resource-limited countries, and data on their incidence by number of device days are not available.<br />Methods: Prospective, surveillance study on PVCR-BSI conducted from September 1, 2013, to May 31, 2019, in 727 intensive care units (ICUs), by members of the International Nosocomial Infection Control Consortium (INICC), from 268 hospitals in 141 cities of 42 countries of Africa, the Americas, Eastern Mediterranean, Europe, South East Asia, and Western Pacific regions. For this research, we applied definition and criteria of the CDC NHSN, methodology of the INICC, and software named INICC Surveillance Online System.<br />Results: We followed 149,609 ICU patients for 731,135 bed days and 743,508 short-term peripheral venous catheter (PVC) days. We identified 1,789 PVCR-BSIs for an overall rate of 2.41 per 1,000 PVC days. Mortality in patients with PVC but without PVCR-BSI was 6.67%, and mortality was 18% in patients with PVC and PVCR-BSI. The length of stay of patients with PVC but without PVCR-BSI was 4.83 days, and the length of stay was 9.85 days in patients with PVC and PVCR-BSI. Among these infections, the microorganism profile showed 58% gram-negative bacteria: Escherichia coli (16%), Klebsiella spp (11%), Pseudomonas aeruginosa (6%), Enterobacter spp (4%), and others (20%) including Serratia marcescens. Staphylococcus aureus were the predominant gram-positive bacteria (12%).<br />Conclusions: PVCR-BSI rates in INICC ICUs were much higher than rates published from industrialized countries. Infection prevention programs must be implemented to reduce the incidence of PVCR-BSIs in resource-limited countries.

Details

Language :
English
ISSN :
1559-6834
Volume :
41
Issue :
5
Database :
MEDLINE
Journal :
Infection control and hospital epidemiology
Publication Type :
Academic Journal
Accession number :
32183925
Full Text :
https://doi.org/10.1017/ice.2020.20