Back to Search
Start Over
Coronary ostial eccentricity in severe aortic stenosis: Guidance for BASILICA transcatheter leaflet laceration.
- Source :
-
Journal of cardiovascular computed tomography [J Cardiovasc Comput Tomogr] 2020 Nov - Dec; Vol. 14 (6), pp. 516-519. Date of Electronic Publication: 2020 Mar 19. - Publication Year :
- 2020
-
Abstract
- Background: Eccentricity of coronary ostial positions in relation to the aortic valve cusp may influence the target laceration location in BASILICA (Bioprosthetic or native Aortic Scallop Intentional Laceration to prevent Coronary Artery obstruction). Eccentricity of the coronary ostia in relation to coronary cusps of native and valve-in-valve transcatheter aortic valve replacement (TAVR) was not well described before.<br />Methods: A total of 121 pre-TAVR patients' CT data (72 native valves TAVR and 49 bioprosthetic surgical valves TAVR) was included and coronary ostial eccentricity angles were measured and compared. Coronary ostial angles were measured between mid-cusp line to coronary ostium in CT perpendicular images.<br />Results: In the overall cohort, the right coronary artery (RCA) had an eccentric origin in the majority of cases, favoring the commissure between the right and the non coronary cusp (17.0°, IQR; 10-25). On the other hand, the left coronary artery (LCA) originated most commonly near center of the cusp position (0°, IQR; -8 -7.5) In comparison of native and bioprosthetic valves, RCA ostial angles were more eccentric in native valves (19.0°, IQR; 12-26) than in bioprosthetic valves (14.0°, IQR; 3-20) (p = 0.004). Whereas, LCA ostial angle has no significant differences between native valves (-2.0°, IQR;-7.75-5.75) and bioprosthetic valves (1°, IQR;-8-13), (p = 0.6).<br />Conclusion: RCA ostia often have an eccentric origin towards the non-coronary cusp, especially in native aortic valves, while LCA ostia commonly originate near the center of the cusp. This finding may contribute to better performance of BASILICA procedures.<br />Competing Interests: Declaration of competing interest The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: Dr HC Wijeysundera received research funding from Medtronic Inc and Edwards Lifesciences. Dr.JM McCabe is a consultant to Edwards LifeSciences, Boston Scientific. Dr N Piazza is a consultant and proctor for Medtronic and Microport. D Dvir, is a consultant to Edwards Lifesciences, Medtronic, Gore, Jena, Abbott. All other authors have no potential conflicts of interest to disclose with regard to any part of the data or results in this report.<br /> (Copyright © 2020 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.)
- Subjects :
- Aged
Aortic Valve diagnostic imaging
Aortic Valve Stenosis diagnostic imaging
Coronary Stenosis diagnostic imaging
Coronary Stenosis etiology
Female
Humans
Male
Predictive Value of Tests
Prosthesis Design
Risk Factors
Severity of Illness Index
Transcatheter Aortic Valve Replacement adverse effects
Treatment Outcome
Aortic Valve surgery
Aortic Valve Stenosis surgery
Bioprosthesis
Computed Tomography Angiography
Coronary Angiography
Coronary Stenosis prevention & control
Coronary Vessels diagnostic imaging
Heart Valve Prosthesis
Multidetector Computed Tomography
Transcatheter Aortic Valve Replacement instrumentation
Subjects
Details
- Language :
- English
- ISSN :
- 1876-861X
- Volume :
- 14
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- Journal of cardiovascular computed tomography
- Publication Type :
- Academic Journal
- Accession number :
- 32199758
- Full Text :
- https://doi.org/10.1016/j.jcct.2020.02.006