Back to Search
Start Over
Evaluation of length of stay after transfemoral transcatheter aortic valve implantation with SAPIEN 3 prosthesis: A French multicentre prospective observational trial.
- Source :
-
Archives of cardiovascular diseases [Arch Cardiovasc Dis] 2020 Jun - Jul; Vol. 113 (6-7), pp. 391-400. Date of Electronic Publication: 2020 May 14. - Publication Year :
- 2020
-
Abstract
- Background: Complications decrease after transfemoral transcatheter aortic valve implantation (TAVI), and early discharge is feasible and safe in selected populations.<br />Aims: To evaluate length of stay (LOS) and reasons for prolonged hospitalisation after transfemoral TAVI in unselected patients.<br />Methods: Patients with severe aortic stenosis, who had transfemoral TAVI with the SAPIEN 3 prosthesis using exclusively local anaesthesia, were prospectively and consecutively included at five French high-volume centres. LOS was calculated from TAVI procedure to discharge. Reasons for prolonged hospitalisation (i.e.>3 days) were evaluated.<br />Results: Between 2017 and 2018, 293 patients were included, with a mean age of 82.4±6.5 years and a mean logistic EuroSCORE of 13.7±9.0%. The in-hospital mortality rate was 1.4%. The median LOS was 5 (3-7) days, and varied considerably between centres (from 2 to 7 days). Sixty-four (21.8%) patients were discharged within 3 days after transfemoral TAVI. Reported reasons for prolonged hospitalisation were complications in 62.2%, loss of autonomy in 3.1%, discharge refusal in 2.2% and logistical reasons in 0.9%. In 31.6% of cases, the investigators reported no apparent reasons.<br />Conclusions: The results of our study suggest that LOS after transfemoral TAVI, using the SAPIEN 3 prosthesis and a minimalist approach, varies considerably between centres. In almost a third of cases, hospitalisation was prolonged without any apparent reason. Efforts should be made to educate centres to reduce LOS.<br /> (Copyright © 2020 Elsevier Masson SAS. All rights reserved.)
- Subjects :
- Aged
Aged, 80 and over
Aortic Valve diagnostic imaging
Aortic Valve physiopathology
Aortic Valve Stenosis diagnostic imaging
Aortic Valve Stenosis mortality
Aortic Valve Stenosis physiopathology
Female
Hospital Mortality
Humans
Male
Patient Discharge
Prospective Studies
Registries
Risk Factors
Severity of Illness Index
Time Factors
Treatment Outcome
Aortic Valve surgery
Aortic Valve Stenosis surgery
Catheterization, Peripheral adverse effects
Femoral Artery
Length of Stay
Transcatheter Aortic Valve Replacement adverse effects
Transcatheter Aortic Valve Replacement mortality
Subjects
Details
- Language :
- English
- ISSN :
- 1875-2128
- Volume :
- 113
- Issue :
- 6-7
- Database :
- MEDLINE
- Journal :
- Archives of cardiovascular diseases
- Publication Type :
- Academic Journal
- Accession number :
- 32418883
- Full Text :
- https://doi.org/10.1016/j.acvd.2019.11.010