Balloon Versus Self-Expandable Valve for the Treatment of Bicuspid Aortic Valve Stenosis: Insights From the BEAT International Collaborative Registrys.
- Source :
-
Circulation. Cardiovascular interventions [Circ Cardiovasc Interv] 2020 Jul; Vol. 13 (7), pp. e008714. Date of Electronic Publication: 2020 Jul 10. - Publication Year :
- 2020
-
Abstract
- Background: Large data comparing the performance of new-generation self-expandable versus balloon-expandable transcatheter heart valves in bicuspid aortic stenosis are lacking. We aim to compare the safety and performance of balloon-expandable and self-expandable transcatheter heart valves in the treatment of bicuspid aortic stenosis.<br />Methods: The BEAT (balloon versus self-expandable valve for the treatment of bicuspid aortic valve stenosis) registry included 353 consecutive patients who underwent transcatheter aortic valve implantation using new-generation Evolut R/PRO or Sapien 3 valves in bicuspid aortic valve.<br />Results: A total of 353 patients (n=242 [68.6%] treated with Sapien 3 and n=111 [68.6%] treated with Evolut R (n=70)/PRO [n=41]) were included. Mean age was 77.8±8.3 years and mean Society of Thoracic Surgeons Predicted Risk of Mortality was 4.4±3.3%. Valve Academic Research Consortium-2 device success was similar between Sapien 3 and Evolut R/PRO (85.6% versus 87.2%; P =0.68). In the Sapien 3 group, 4 patients experienced annular rupture whereas this complication did not occur in the Evolut R/PRO group. After propensity score matching, Valve Academic Research Consortium-2 device success was similar between both groups (Sapien 3=85.7% versus Evolut R/Pro=84.4%; P =0.821). Both in the overall and in the matched population, no differences in the rate of permanent pacemaker implant were observed. At 1-year follow-up, the rate of overall death and cardiovascular death were similar between the 2 groups. In the unmatched population, the 1-year echocardiographic follow-up demonstrated similar rate of moderate-to-severe paravalvular aortic regurgitation (Evolut R/PRO 10.5% versus Sapien 3 4.2%, P =0.077); however, after propensity matching, the rate of moderate-to-severe paravalvular leak became significantly higher among patients treated with self-expandable valves (9.3% versus 0%; P =0.043).<br />Conclusions: Our study confirms the feasibility of both Sapien 3 and Evolut R/PRO implantation in bicuspid aortic valve anatomy; a higher rate of moderate-severe paravalvular aortic regurgitation was observed in the Evolut R/PRO group at 1-year follow-up in the matched cohort, although patients treated with balloon-expandable valve had a higher rate of annular rupture.
- Subjects :
- Aged
Aged, 80 and over
Aortic Valve abnormalities
Aortic Valve diagnostic imaging
Aortic Valve physiopathology
Aortic Valve Stenosis diagnostic imaging
Aortic Valve Stenosis physiopathology
Bicuspid Aortic Valve Disease diagnostic imaging
Bicuspid Aortic Valve Disease physiopathology
Europe
Feasibility Studies
Female
Hemodynamics
Humans
Male
Prosthesis Design
Recovery of Function
Registries
Risk Assessment
Risk Factors
Time Factors
Transcatheter Aortic Valve Replacement adverse effects
Treatment Outcome
Aortic Valve surgery
Aortic Valve Stenosis surgery
Balloon Valvuloplasty adverse effects
Bicuspid Aortic Valve Disease surgery
Heart Valve Prosthesis
Transcatheter Aortic Valve Replacement instrumentation
Subjects
Details
- Language :
- English
- ISSN :
- 1941-7632
- Volume :
- 13
- Issue :
- 7
- Database :
- MEDLINE
- Journal :
- Circulation. Cardiovascular interventions
- Publication Type :
- Academic Journal
- Accession number :
- 32646304
- Full Text :
- https://doi.org/10.1161/CIRCINTERVENTIONS.119.008714