Back to Search Start Over

Balloon Versus Self-Expandable Valve for the Treatment of Bicuspid Aortic Valve Stenosis: Insights From the BEAT International Collaborative Registrys.

Authors :
Mangieri A
Tchetchè D
Kim WK
Pagnesi M
Sinning JM
Landes U
Kornowski R
De Backer O
Nickenig G
Ielasi A
De Biase C
Søndergaard L
De Marco F
Montorfano M
Chiarito M
Regazzoli D
Stefanini G
Presbitero P
Toggweiler S
Tamburino C
Immè S
Tarantini G
Sievert H
Schäfer U
Kempfert J
Wöehrle J
Gallo F
Laricchia A
Latib A
Giannini F
Colombo A
Source :
Circulation. Cardiovascular interventions [Circ Cardiovasc Interv] 2020 Jul; Vol. 13 (7), pp. e008714. Date of Electronic Publication: 2020 Jul 10.
Publication Year :
2020

Abstract

Background: Large data comparing the performance of new-generation self-expandable versus balloon-expandable transcatheter heart valves in bicuspid aortic stenosis are lacking. We aim to compare the safety and performance of balloon-expandable and self-expandable transcatheter heart valves in the treatment of bicuspid aortic stenosis.<br />Methods: The BEAT (balloon versus self-expandable valve for the treatment of bicuspid aortic valve stenosis) registry included 353 consecutive patients who underwent transcatheter aortic valve implantation using new-generation Evolut R/PRO or Sapien 3 valves in bicuspid aortic valve.<br />Results: A total of 353 patients (n=242 [68.6%] treated with Sapien 3 and n=111 [68.6%] treated with Evolut R (n=70)/PRO [n=41]) were included. Mean age was 77.8±8.3 years and mean Society of Thoracic Surgeons Predicted Risk of Mortality was 4.4±3.3%. Valve Academic Research Consortium-2 device success was similar between Sapien 3 and Evolut R/PRO (85.6% versus 87.2%; P =0.68). In the Sapien 3 group, 4 patients experienced annular rupture whereas this complication did not occur in the Evolut R/PRO group. After propensity score matching, Valve Academic Research Consortium-2 device success was similar between both groups (Sapien 3=85.7% versus Evolut R/Pro=84.4%; P =0.821). Both in the overall and in the matched population, no differences in the rate of permanent pacemaker implant were observed. At 1-year follow-up, the rate of overall death and cardiovascular death were similar between the 2 groups. In the unmatched population, the 1-year echocardiographic follow-up demonstrated similar rate of moderate-to-severe paravalvular aortic regurgitation (Evolut R/PRO 10.5% versus Sapien 3 4.2%, P =0.077); however, after propensity matching, the rate of moderate-to-severe paravalvular leak became significantly higher among patients treated with self-expandable valves (9.3% versus 0%; P =0.043).<br />Conclusions: Our study confirms the feasibility of both Sapien 3 and Evolut R/PRO implantation in bicuspid aortic valve anatomy; a higher rate of moderate-severe paravalvular aortic regurgitation was observed in the Evolut R/PRO group at 1-year follow-up in the matched cohort, although patients treated with balloon-expandable valve had a higher rate of annular rupture.

Details

Language :
English
ISSN :
1941-7632
Volume :
13
Issue :
7
Database :
MEDLINE
Journal :
Circulation. Cardiovascular interventions
Publication Type :
Academic Journal
Accession number :
32646304
Full Text :
https://doi.org/10.1161/CIRCINTERVENTIONS.119.008714