Back to Search Start Over

Vessel-selective 4D-MR angiography using super-selective pseudo-continuous arterial spin labeling may be a useful tool for assessing brain AVM hemodynamics.

Authors :
Togao O
Obara M
Helle M
Yamashita K
Kikuchi K
Momosaka D
Kikuchi Y
Nishimura A
Arimura K
Wada T
Murazaki H
Iihara K
Van Cauteren M
Hiwatashi A
Source :
European radiology [Eur Radiol] 2020 Dec; Vol. 30 (12), pp. 6452-6463. Date of Electronic Publication: 2020 Jul 21.
Publication Year :
2020

Abstract

Objectives: To evaluate the usefulness of 4D-MR angiography based on super-selective pseudo-continuous ASL combined with keyhole and view-sharing (4D-S-PACK) for vessel-selective visualization and to examine the ability of this technique to visualize brain arteriovenous malformations (AVMs).<br />Methods: In this retrospective study, 15 patients (ten men and five women, mean age 44.0 ± 16.9 years) with brain AVMs were enrolled. All patients were imaged with 4D-PACK (non-selective), 4D-S-PACK, and digital subtraction angiography (DSA). Observers evaluated vessel selectivity, identification of feeding arteries and venous drainage patterns, visualization scores, and contrast-to-noise ratio (CNR) for each AVM component. Measurements were compared between the MR methods.<br />Results: Vessel selectivity was graded 4 in 43/45 (95.6%, observer 1) and 42/45 (93.3%, observer 2) territories and graded 3 in two (observer 1) and three (observer 2) territories. The sensitivity and specificity for identification of feeding arteries for both observers was 88.9% and 100% on 4D-PACK, and 100% and 100% on 4D-S-PACK, respectively. For venous drainage, the sensitivity and specificity was 100% on both methods for observer 1. The sensitivity and specificity for observer 2 was 94.4% and 83.3% on 4D-PACK, and 94.4% and 91.7% on 4D-S-PACK, respectively. The CNRs at the timepoint of 1600 ms were slightly lower in 4D-S-PACK than in 4D-PACK for all AVM components (Feeding artery, p = .02; nidus, p = .001; and draining artery, p = .02). The visualization scores for both observers were not significantly different between 4D-PACK and 4D-S-PACK for all components.<br />Conclusions: 4D-S-PACK could be a useful non-invasive clinical tool for assessing hemodynamics in brain AVMs.<br />Key Points: • The 4D-MR angiography based on super-selective pseudo-continuous arterial spin labeling combined with CENTRA-keyhole and view-sharing (4D-S-PACK) enabled excellent vessel selectivity. • The 4D-S-PACK enabled the perfect identification of feeding arteries of brain arteriovenous malformation (AVM). • 4D-S-PACK could be a non-invasive clinical tool for assessing hemodynamics in brain AVMs.

Details

Language :
English
ISSN :
1432-1084
Volume :
30
Issue :
12
Database :
MEDLINE
Journal :
European radiology
Publication Type :
Academic Journal
Accession number :
32696254
Full Text :
https://doi.org/10.1007/s00330-020-07057-4