Back to Search
Start Over
The Italian Multicentre Registry of Fenestrated Anaconda™ Endografts for Complex Abdominal Aortic Aneurysms Repair.
- Source :
-
European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery [Eur J Vasc Endovasc Surg] 2020 Aug; Vol. 60 (2), pp. 181-191. Date of Electronic Publication: 2020 Jul 21. - Publication Year :
- 2020
-
Abstract
- Objective: The aim was to describe the outcomes of the Anaconda™ Fenestrated endograft Italian Registry for complex aortic aneurysms (AAAs), unsuitable for standard endovascular aneurysm repair (EVAR).<br />Methods: Between 2012 and 2018 patients with a proximal neck unsuitable for standard EVAR, treated with the fenestrated Anaconda™ endograft, were prospectively enrolled in a dedicated database. Endpoints were peri-operative technical success (TS) and evaluation of type Ia/b or 3 endoleaks (T1/3 EL), target visceral vessel (TVV) occlusion, re-interventions, and AAA related mortality at 30 days, six months, and later follow up.<br />Results: One hundred twenty seven patients (74 ± 7 years, American Society Anesthesiology (ASA) II/III/IV: 12/85/30) were included in the study in 49 Italian Vascular Surgery Units (83 juxta/para-renal AAA, 13 type IV thoraco-abdominal AAA, 16 T1aEL post EVAR, and 15 short neck AAA). Configurations with one, two, three, and four fenestrations were used in 5, 56, 39, and 27 cases, respectively, for a total of 342 visceral vessels. One hundred and eight (85%) bifurcated and 19 (15%) tube endografts were implanted. In 35% (44/127) of cases the endograft was repositioned during the procedure, and 37% (128/342) of TVV were cannulated from brachial access. TS was 87% (111/127): five T1EL, six T3EL (between fenestration and vessel stent), and six loss of visceral vessels (one patient with a Type Ia EL had also a TVV loss) occurred. Thirty day mortality was 4% (5/127). Two of the five T1EL resolved spontaneously at 30 days. The overall median follow up was 21 ± 16 months; one T1EL (5%) occurred at six months and one T3EL (4%) at the three year follow up. Another two (3%) TVV occlusions occurred at six months and five (3%) at three years. The re-intervention rate at the 30 days, six months, and three year follow up was 5%, 7%, and 18 ± 5%, respectively.<br />Conclusion: The fenestrated Anaconda™ endograft is effective in the treatment of complex AAA. Some structure properties, such as the re-positionability and the possibility of cannulation from above, are specific characteristics helpful for the treatment of some complex anatomies.<br /> (Copyright © 2020 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.)
- Subjects :
- Aged
Aged, 80 and over
Aortic Aneurysm, Abdominal diagnostic imaging
Aortic Aneurysm, Abdominal mortality
Aortic Aneurysm, Thoracic diagnostic imaging
Aortic Aneurysm, Thoracic mortality
Blood Vessel Prosthesis Implantation adverse effects
Blood Vessel Prosthesis Implantation mortality
Endoleak etiology
Endoleak therapy
Endovascular Procedures adverse effects
Endovascular Procedures mortality
Female
Humans
Italy
Male
Prospective Studies
Prosthesis Design
Registries
Risk Factors
Time Factors
Treatment Outcome
Aortic Aneurysm, Abdominal surgery
Aortic Aneurysm, Thoracic surgery
Blood Vessel Prosthesis
Blood Vessel Prosthesis Implantation instrumentation
Endovascular Procedures instrumentation
Subjects
Details
- Language :
- English
- ISSN :
- 1532-2165
- Volume :
- 60
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery
- Publication Type :
- Academic Journal
- Accession number :
- 32709467
- Full Text :
- https://doi.org/10.1016/j.ejvs.2020.04.032