Back to Search Start Over

Efficacy of silicone soft reliner on the obturator prosthesis after maxillectomy for oral malignant tumors: A single-arm prospective interventional study.

Authors :
Yanamoto S
Soutome S
Murata M
Kawakita A
Yamaguchi E
Yoshida K
Kurogi T
Kuroshima S
Murata H
Sawase T
Umeda M
Source :
Clinical and experimental dental research [Clin Exp Dent Res] 2020 Dec; Vol. 6 (6), pp. 612-617. Date of Electronic Publication: 2020 Sep 08.
Publication Year :
2020

Abstract

Background: There is insufficient evidence for the efficacy of silicone soft reliner on the obturator prosthesis after maxillectomy for oral malignant tumors.<br />Objective: To verify the efficacy of silicone soft reliner on the obturator prosthesis after maxillectomy, by evaluating masticatory performance and quality of life (QoL).<br />Methods: This was a single-arm prospective interventional study, verifying the efficacy of silicone soft reliner (GC RELINE II®) on the maxillary obturator prosthesis. Data were obtained from a comparison of the endpoints after 14 days of continuous use of acrylic and silicone soft-lined prostheses. The primary endpoint was masticatory performance. The secondary endpoints were occlusal performance and oral health-related QoL (OHRQoL). The masticatory performance, occlusal performance, and OHRQoL were assessed by glucose concentration, maximum bite force, and the Japanese version of Oral Health Impact Profile (OHIP-J49), respectively.<br />Results: This study included five patients (two males, three females), aged between 71 and 88 years, with a median of 74 years. The median of glucose concentration indicated a statistically significant improvement between the acrylic resin (99.6 mg/dL) and silicone soft reliner (126.0 mg/dL) obturator prosthesis (p = .043). There was no significant difference in the median of maximum bite force between the acrylic resin (302.0 N) and silicone soft reliner (250.0 N) obturator prosthesis (p = .893). Functional limitations domain of the OHIP-J49 indicated a statistically significant improvement between the acrylic resin and silicone soft reliner obturator prosthesis (p = .043).<br />Conclusions: This study indicated that an obturator relined with soft silicone improved masticatory performance and the OHRQoL post-maxillectomy.<br /> (© 2020 The Authors. Clinical and Experimental Dental Research published by John Wiley & Sons Ltd.)

Details

Language :
English
ISSN :
2057-4347
Volume :
6
Issue :
6
Database :
MEDLINE
Journal :
Clinical and experimental dental research
Publication Type :
Academic Journal
Accession number :
32896981
Full Text :
https://doi.org/10.1002/cre2.326