Back to Search Start Over

How are peri-implant fractures below short versus long cephalomedullary nails different?

Authors :
Goodnough LH
Salazar BP
Furness J
Feng JE
DeBaun MR
Campbell ST
Lucas JF
Cross WW
Leucht P
Grant KD
Gardner MJ
Bishop JA
Source :
European journal of orthopaedic surgery & traumatology : orthopedie traumatologie [Eur J Orthop Surg Traumatol] 2021 Apr; Vol. 31 (3), pp. 421-427. Date of Electronic Publication: 2020 Sep 09.
Publication Year :
2021

Abstract

Background: Cephalomedullary nails are a commonly used implant for the treatment of many pertrochanteric femur fractures and are available in short and long configurations. There is no consensus on ideal nail length. Relative advantages can be ascribed to short and long intramedullary nails, yet both implant styles share the potentially devastating complication of peri-implant fracture. Determining the clinical sequelae after fractures below nails of different lengths would provide valuable information for surgeons choosing between short or long nails. Thus, the purpose of the study was to compare injury patterns and treatment outcomes following peri-implant fractures below short or long cephalomedullary nails.<br />Methods: This was a multicenter retrospective cohort study that identified 33 patients referred for treatment of peri-implant fractures below short and long cephalomedullary nails (nā€‰=ā€‰19 short, nā€‰=ā€‰14 long). We compared fracture pattern, treatment strategy, complications, and outcomes between these two groups.<br />Results: Short nails were associated with more diaphyseal fractures (odds ratio [OR] 13.75, CI 2.2-57.9, p 0.002), which were treated more commonly with revision intramedullary nailing (OR, infinity; p 0.01), while long nails were associated with distal metaphyseal fractures (OR 13.75, CI 2.2-57.9, p 0.002), which were treated with plate and screw fixation (p 0.002). After peri-implant fracture, there were no differences in blood loss, operative time, weight bearing status, or complication rates based on the length of the initial nail. In patients treated with revision nailing, there was greater estimated blood loss (EBL, median 300 cc, interquartile range [IQR] 250-1200 vs median 200 cc, IQR 100-300, p 0.03), blood product utilization and complication rates (OR 11.1, CI 1.1-135.7, p 0.03), but a trend toward unrestricted post-operative weight-bearing compared to patients treated with plate and screw constructs.<br />Conclusion: Understanding fracture patterns and patient outcomes after fractures below nails of different lengths will help surgeons make more informed implant choices when treating intertrochanteric hip fractures. Revision to a long nail for the treatment of fractures at the tip of a short nail may be associated with increased patient morbidity.

Details

Language :
English
ISSN :
1432-1068
Volume :
31
Issue :
3
Database :
MEDLINE
Journal :
European journal of orthopaedic surgery & traumatology : orthopedie traumatologie
Publication Type :
Academic Journal
Accession number :
32909108
Full Text :
https://doi.org/10.1007/s00590-020-02785-1