Back to Search Start Over

No SARS-CoV-2 Neutralization by Intravenous Immunoglobulins Produced From Plasma Collected Before the 2020 Pandemic.

Authors :
Schwaiger J
Karbiener M
Aberham C
Farcet MR
Kreil TR
Source :
The Journal of infectious diseases [J Infect Dis] 2020 Nov 13; Vol. 222 (12), pp. 1960-1964.
Publication Year :
2020

Abstract

The 2020 SARS-CoV-2 pandemic is caused by a zoonotic coronavirus transmitted to humans, similar to earlier events. Whether the other, seasonally circulating coronaviruses induce cross-reactive, potentially even cross-neutralizing, antibodies to the new species in humans is unclear. The question is particularly relevant for people with immune deficiencies, as their health depends on treatment with immunoglobulin preparations that need to contain neutralizing antibodies against the pathogens in their environment. Testing 54 intravenous immunoglobulin preparations, produced from plasma collected in Europe and the United States, confirmed highly potent neutralization of a seasonal coronavirus; however, no cross-neutralization of the new SARS-CoV-2 was seen.<br /> (© The Author(s) 2020. Published by Oxford University Press for the Infectious Diseases Society of America.)

Details

Language :
English
ISSN :
1537-6613
Volume :
222
Issue :
12
Database :
MEDLINE
Journal :
The Journal of infectious diseases
Publication Type :
Academic Journal
Accession number :
32941626
Full Text :
https://doi.org/10.1093/infdis/jiaa593