Back to Search Start Over

Motion correction methods for MRS: experts' consensus recommendations.

Authors :
Andronesi OC
Bhattacharyya PK
Bogner W
Choi IY
Hess AT
Lee P
Meintjes EM
Tisdall MD
Zaitzev M
van der Kouwe A
Source :
NMR in biomedicine [NMR Biomed] 2021 May; Vol. 34 (5), pp. e4364. Date of Electronic Publication: 2020 Jul 20.
Publication Year :
2021

Abstract

Long acquisition times due to intrinsically low signal-to-noise ratio and the need for highly homogeneous B <subscript>0</subscript> field make MRS particularly susceptible to motion or scanner instability compared with MRI. Motion-induced changes in both localization and shimming (ie B <subscript>0</subscript> homogeneity) degrade MRS data quality. To mitigate the effects of motion three approaches can be employed: (1) subject immobilization, (2) retrospective correction, and (3) prospective real-time correction using internal and/or external tracking methods. Prospective real-time correction methods can simultaneously update localization and the B <subscript>0</subscript> field to improve MRS data quality. While localization errors can be corrected with both internal (navigators) and external (optical camera, NMR probes) tracking methods, the B <subscript>0</subscript> field correction requires internal navigator methods to measure the B <subscript>0</subscript> field inside the imaged volume and the possibility to update the scanner shim hardware in real time. Internal and external tracking can rapidly update the MRS localization with submillimeter and subdegree precision, while scanner frequency and first-order shims of scanner hardware can be updated by internal methods every sequence repetition. These approaches are most well developed for neuroimaging, for which rigid transformation is primarily applicable. Real-time correction greatly improves the stability of MRS acquisition and quantification, as shown in clinical studies on subjects prone to motion, including children and patients with movement disorders, enabling robust measurement of metabolite signals including those with low concentrations, such as gamma-aminobutyric acid and glutathione. Thus, motion correction is recommended for MRS users and calls for tighter integration and wider availability of such methods by MR scanner manufacturers.<br /> (© 2020 John Wiley & Sons, Ltd.)

Details

Language :
English
ISSN :
1099-1492
Volume :
34
Issue :
5
Database :
MEDLINE
Journal :
NMR in biomedicine
Publication Type :
Academic Journal
Accession number :
33089547
Full Text :
https://doi.org/10.1002/nbm.4364