Back to Search Start Over

Contemporary procedural trends of Watchman percutaneous left atrial appendage occlusion in the United States.

Authors :
Munir MB
Khan MZ
Darden D
Pasupula DK
Balla S
Han FT
Reeves R
Hsu JC
Source :
Journal of cardiovascular electrophysiology [J Cardiovasc Electrophysiol] 2021 Jan; Vol. 32 (1), pp. 83-92. Date of Electronic Publication: 2020 Nov 11.
Publication Year :
2021

Abstract

Objective: To determine trends in real-world utilization and in-hospital adverse events from Watchman implantation since its approval by the Food and Drug Administration in 2015.<br />Background: The risk of embolic stroke caused by atrial fibrillation is reduced by oral anticoagulants, but not all patients can tolerate long-term anticoagulation. Left atrial appendage occlusion with the Watchman device has emerged as an alternative therapy.<br />Methods: This was a retrospective cohort study utilizing data from National Inpatient Sample for calendar years 2015-2017. The outcomes assessed in this study were associated complications, in-hospital mortality, and resource utilization trends after Watchman implantation. Trends analysis were performed using analysis of variance. Multivariable adjusted logistic regression analysis was performed to determine predictors of mortality.<br />Results: A total of 17 700 patients underwent Watchman implantation during the study period. There was a significantly increased trend in the number of Watchman procedures performed over the study years (from 1195 in 2015 to 11 165 devices in 2017, p < .01). A significant decline in the rate of complications (from 26.4% in 2015% to 7.9% in 2017, p < .01) and inpatient mortality (from 1.3% in 2015% to 0.1% in 2017, p < .01) were noted. Predictors of in-hospital mortality included a higher CHA <subscript>2</subscript> DS <subscript>2</subscript> -VASc score (odds ratio [OR]: 2.61 per 1-point increase, 95% confidence interval [CI]: 1.91-3.57), chronic blood loss anemia (OR: 3.63, 95% CI: 1.37-9.61) and coagulopathy (OR: 4.90, 95% CI: 2.32-10.35).<br />Conclusion: In contemporary United States clinical practice, Watchman utilization has increased significantly since approval in 2015, while complications and in-patient mortality have declined.<br /> (© 2020 Wiley Periodicals LLC.)

Details

Language :
English
ISSN :
1540-8167
Volume :
32
Issue :
1
Database :
MEDLINE
Journal :
Journal of cardiovascular electrophysiology
Publication Type :
Academic Journal
Accession number :
33155356
Full Text :
https://doi.org/10.1111/jce.14804