A young lady presented with very high vault and fixed dilated pupil along with optic capture of the implantable collamer lens (ICL). After thorough evaluation and ruling out the ICL sizing error, the optic capture was relieved and the ICL was rotated into vertical position. Single-pass four throw pupilloplasty was performed for the fixed dilated pupil. Postoperatively the ICL vault and the pupil size decreased and patient was asymptomatic. This case highlights a successful outcome of rotation of a nontoric ICL to reduce the high vaulting and optic capture along with single-pass four throw pupilloplasty.<br />Competing Interests: None