Back to Search Start Over

Comparison of four commercial RT-PCR diagnostic kits for COVID-19 in China.

Authors :
Shen L
Cui S
Zhang D
Lin C
Chen L
Wang Q
Source :
Journal of clinical laboratory analysis [J Clin Lab Anal] 2021 Jan; Vol. 35 (1), pp. e23605. Date of Electronic Publication: 2020 Dec 15.
Publication Year :
2021

Abstract

We compared the sensitivity and specificity of four commercial coronavirus disease (COVID-19) diagnostic kits using real-time reverse transcription-polymerase chain reaction (RT-PCR). Kits I-IV approved by the State Drug Administration of China were selected, and the detection targets were ORF1ab gene and N gene. Specificity was evaluated by detecting other respiratory viruses. The sensitivity and batch effect of each kit were evaluated by testing 10-fold dilutions of RNA. Clinical application was verified by testing nasopharyngeal swab and sputum specimens from COVID-19 patients. Among the 78 cases infected by other respiratory viruses, no amplification curve was observed using these four COVID-19 RT-PCR kits. The minimum detection limits of kits I-IV were 10 <superscript>-6</superscript> , 10 <superscript>-5</superscript> , 10 <superscript>-5</superscript> , and 10 <superscript>-6</superscript> dilutions, respectively, and concentrations were 10 copies/mL (10 <superscript>-5</superscript> dilution) and 1 copies/mL (10 <superscript>-6</superscript> dilution). The sensitivities of kits I-IV detected using 142 nasopharyngeal swab specimens from COVID-19 patients were 91.55%, 81.69%, 80.28%, and 90.85%, respectively, while they were 92.68%, 85.37%, 82.93%, and 93.90%, respectively, for the 82 sputum samples. The specificity of each kit was 100.00% (77/77). The total expected detection rate using sputum samples was 88.59% (691/780) higher than 86.15% (672/780) of nasopharyngeal swabs. Comparison of nasopharyngeal swab and sputum samples from the same COVID-19 patient led to the detection of ORF1ab and N genes in 16 (100%) sputum samples; only ORF1ab and N genes were detected in 12 (75%) and 14 (87.5%) nasopharyngeal swab specimens, respectively. In conclusion, comparison of commercial COVID-19 RT-PCR kits should be performed before using a new batch of such kits in routine diagnostics.<br /> (© 2020 The Authors. Journal of Clinical Laboratory Analysis Published by Wiley Periodicals LLC.)

Details

Language :
English
ISSN :
1098-2825
Volume :
35
Issue :
1
Database :
MEDLINE
Journal :
Journal of clinical laboratory analysis
Publication Type :
Academic Journal
Accession number :
33320386
Full Text :
https://doi.org/10.1002/jcla.23605