Back to Search Start Over

Optimizing the Use of High-Sensitivity Troponin Assays for the Early Rule-out of Myocardial Infarction in Patients Presenting with Chest Pain: A Systematic Review.

Authors :
Westwood ME
Armstrong N
Worthy G
Fayter D
Ramaekers BLT
Grimm S
Buksnys T
Ross J
Mills NL
Body R
Collinson PO
Timmis A
Kleijnen J
Source :
Clinical chemistry [Clin Chem] 2021 Jan 08; Vol. 67 (1), pp. 237-244.
Publication Year :
2021

Abstract

Background: We assessed the accuracy and clinical effectiveness of high-sensitivity cardiac troponin (hs-cTn) assays for early rule-out of non-ST-segment elevation myocardial infarction (NSTEMI) in adults presenting with acute chest pain.<br />Methods: Sixteen databases were searched to September 2019. Review methods followed published guidelines. The bivariate model was used to estimate summary sensitivity and specificity with 95% confidence intervals for meta-analyses involving 4 or more studies, otherwise random-effects logistic regression was used.<br />Results: Thirty-seven studies (124 publications) were included in the review. The hs-cTn test strategies evaluated in the included studies were defined by the combination of 4 factors (assay, number of tests, timing of tests, and threshold concentration or change in concentration between tests). Clinical opinion indicated a minimum acceptable sensitivity of 97%. A single test at presentation using a threshold at or near the assay limit of detection could reliably rule-out NSTEMI for a range of hs-cTn assays. Serial testing strategies, which include an immediate rule-out step, increased the proportion ruled out without loss of sensitivity. Finally, serial testing strategies without an immediate rule-out step had excellent sensitivity and specificity, but at the expense of the option for immediate patient discharge.<br />Conclusion: Test strategies that comprise an initial rule-out step, based on low hs-cTn concentrations at presentation and a minimum symptom duration, and a second step for those not ruled-out that incorporates a small absolute change in hs-cTn at 1, 2, or 3 hours, produce the highest rule-out rates with a very low risk of missed NSTEMI.<br />Prospero Registration: CRD42019154716.<br /> (© American Association for Clinical Chemistry 2020. All rights reserved. For permissions, please email: journals.permissions@oup.com.)

Details

Language :
English
ISSN :
1530-8561
Volume :
67
Issue :
1
Database :
MEDLINE
Journal :
Clinical chemistry
Publication Type :
Academic Journal
Accession number :
33418577
Full Text :
https://doi.org/10.1093/clinchem/hvaa280