Back to Search
Start Over
Second-Window Indocyanine Green for Visualization of Hemangioblastoma: A Case Report With Two-Dimensional Operative Video.
- Source :
-
Operative neurosurgery (Hagerstown, Md.) [Oper Neurosurg (Hagerstown)] 2021 Feb 16; Vol. 20 (3), pp. E229-E233. - Publication Year :
- 2021
-
Abstract
- Background and Importance: The proper differentiation of neoplastic tissue from adjacent brain parenchyma can pose a great challenge, especially in eloquent areas of the brain. With the novel technique, "Second-Window Indocyanine Green," injection of a near-infrared fluorophore (ICG) allows for intraoperative visualization of tumors by taking advantage of the compromised vasculature surrounding the tumor. Thus, such a technique may demonstrate utility for hemangioblastomas, which are hypervascular tumors of the central nervous system.<br />Clinical Presentation: Here we present the case of a 39-yr-old male with a demonstrated cystic mass in the left cerebellum, with additional edema spreading towards the vermis. A total of 5 mg/kg of ICG was delivered intravenously 24 h prior to the operation. The tumor was approached via the infratentorial suboccipital approach. We observed strong near-infrared fluorescence through the intact dura, consistent with the tumor location. Surgical pathology confirmed a final diagnosis of cerebellar hemangioblastoma. There was complete resection of the tumor, with the patient discharged uneventfully.<br />Conclusion: We report the first successful case of fluorescence-guided surgery of a cerebellar hemangioblastoma using near-infrared fluorescence imaging with the Second-Window ICG technique. This joins a growing series of publications that demonstrate the efficacy of a novel application of ICG, a near-infrared fluorophore, in accurate intraoperative visualization of neoplastic tissue. While the use of a dedicated near-infrared platform (ie, the VisionSense Iridium [Visionsense, Philadelphia, Pennsylvania]) yields a higher signal-to-background ratio, a neurosurgical microscope (ie, the Leica OH6 [Leica Microsystems, Wetzlar, Germany]) may also provide a suitable option in cases where fluorescence is very strong.<br /> (© Congress of Neurological Surgeons 2021.)
Details
- Language :
- English
- ISSN :
- 2332-4260
- Volume :
- 20
- Issue :
- 3
- Database :
- MEDLINE
- Journal :
- Operative neurosurgery (Hagerstown, Md.)
- Publication Type :
- Academic Journal
- Accession number :
- 33442750
- Full Text :
- https://doi.org/10.1093/ons/opaa392