Back to Search Start Over

Volumetric absorptive microsampling for the quantification of tacrolimus in capillary blood by high performance liquid chromatography-tandem mass spectrometry.

Authors :
Tron C
Ferrand-Sorre MJ
Querzerho-Raguideau J
Chemouny JM
Houssel-Debry P
Verdier MC
Bellissant E
Lemaitre F
Source :
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences [J Chromatogr B Analyt Technol Biomed Life Sci] 2021 Feb 15; Vol. 1165, pp. 122521. Date of Electronic Publication: 2021 Jan 05.
Publication Year :
2021

Abstract

Volumetric absorptive microsampling (VAMS) is an innovative alternative strategy to venipuncture for monitoring tacrolimus levels in transplant recipients. In this study, we aimed to validate a new high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method for quantifying tacrolimus in blood collected by VAMS. Tacrolimus was extracted from dried blood tips in an original process involving sonication, protein precipitation and salting out. The assay was validated in accordance with EMA and IATDMCT guidelines. For clinical validation, the tacrolimus concentrations measured in liquid venous whole blood (with the reference method) were compared with those measured in capillary whole blood collected simultaneously with VAMS by a nurse. The assay was then used to monitor tacrolimus exposure in transplant recipients. The method was linear, sensitive and fast. Within-day and between-day precisions and overall bias were within ±15%. No significant hematocrit effect was observed. The matrix effect was negligible and recovery exceeded 80% for every concentration and hematocrit levels. Tacrolimus was stable in blood collected by VAMS for 1 week at room temperature, 48 h at 60 °C and 4 °C and 1 month at -80 °C. Clinical validation (n = 42 paired samples) demonstrated a strong correlation between the two methods (r = 0.97 Pearson correlation). Bland-Altman analysis revealed that more than 90% of the differences between VAMS and liquid blood paired concentrations were within the ±20% acceptable range. The method had a satisfactory analytical performance and fulfilled clinical requirements. This minimally invasive VAMS-based assay appears reliable for the determination of tacrolimus levels in blood from transplanted patients.<br /> (Copyright © 2021 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1873-376X
Volume :
1165
Database :
MEDLINE
Journal :
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
Publication Type :
Academic Journal
Accession number :
33486216
Full Text :
https://doi.org/10.1016/j.jchromb.2020.122521