Back to Search Start Over

Adenoma detection by Endocuff-assisted versus standard colonoscopy in an organized screening program: the "ItaVision" randomized controlled trial.

Authors :
Zorzi M
Hassan C
Battagello J
Antonelli G
Pantalena M
Bulighin G
Alicante S
Meggiato T
Rosa-Rizzotto E
Iacopini F
Luigiano C
Monica F
Arrigoni A
Germanà B
Valiante F
Mallardi B
Senore C
Grazzini G
Mantellini P
Source :
Endoscopy [Endoscopy] 2022 Feb; Vol. 54 (2), pp. 138-147. Date of Electronic Publication: 2021 Apr 08.
Publication Year :
2022

Abstract

Background: The Endocuff Vision device (Arc Medical Design Ltd., Leeds, UK) has been shown to increase mucosal exposure, and consequently adenoma detection rate (ADR), during colonoscopy. This nationwide multicenter study assessed possible benefits and harms of using Endocuff Vision in a fecal immunochemical test (FIT)-based screening program.<br />Methods: Patients undergoing colonoscopy after a FIT-positive test were randomized 1:1 to undergo Endocuff-assisted colonoscopy or standard colonoscopy, stratified by sex, age, and screening history. Primary outcome was ADR. Secondary outcomes were ADR stratified by endoscopists' ADR, advanced ADR (AADR), adenomas per colonoscopy (APC), withdrawal time, and adverse events.<br />Results: 1866 patients were enrolled across 13 centers. After exclusions, 1813 (mean age 60.1 years; male 53.8 %) were randomized (908 Endocuff Vision, 905 standard colonoscopy). ADR was significantly higher in the Endocuff Vision arm (47.8 % vs. 40.8 %; relative risk [RR] 1.17, 95 % confidence interval [CI] 1.06-1.30), with no differences between arms regarding size or morphology. When stratifying for endoscopists' ADR, only low detectors (ADR < 33.3 %) showed a statistically significant ADR increase (Endocuff Vision 41.1 % [95 %CI 35.7-46.7] vs. standard colonoscopy 26.0 % [95 %CI 21.3-31.4]). AADR (24.8 % vs. 20.5 %, RR 1.21, 95 %CI 1.02-1.43) and APC (0.94 vs. 0.77; P  = 0.001) were higher in the Endocuff Vision arm. Withdrawal time and adverse events were similar between arms.<br />Conclusion: Endocuff Vision increased ADR in a FIT-based screening program by improving examination of the whole colonic mucosa. Utility was highest among endoscopists with a low ADR.<br />Competing Interests: The authors declare that they have no conflict of interest.<br /> (Thieme. All rights reserved.)

Details

Language :
English
ISSN :
1438-8812
Volume :
54
Issue :
2
Database :
MEDLINE
Journal :
Endoscopy
Publication Type :
Academic Journal
Accession number :
33524994
Full Text :
https://doi.org/10.1055/a-1379-6868