Study of a modified non-contact Hall sensor-based flow transducer using centrifugal and momentum force principle.
- Source :
-
ISA transactions [ISA Trans] 2022 Jan; Vol. 119, pp. 242-251. Date of Electronic Publication: 2021 Feb 16. - Publication Year :
- 2022
-
Abstract
- The paper describes a modified non-contact Hall sensor based centrifugal and momentum force type flow transducer with simple design, low cost and rugged construction. In this transducer two identical permanent magnets are fixed on the two ends of the common balance lever on which sensing U-tube and dummy U-tube are placed at equal distances from the pivot. The movement of lever ends with variation of flow rate, changes the magnet positions with respect to the two identical Hall sensors fixed at two locations just below the magnets. Thus the outputs of the Hall sensors supplied from a stabilized DC source vary with the variation of flow rate. The difference between these outputs is a DC voltage signal non-linearly related with flow rate.<br />Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2021 ISA. Published by Elsevier Ltd. All rights reserved.)