Back to Search Start Over

Comparison of Transcatheter Aortic Valve Replacement between Self-Expanding versus Balloon-Expandable Valves in Patients with Small Aortic Annulus.

Authors :
Lee YJ
Lee SJ
Hong SJ
Shim CY
Ahn CM
Kim JS
Kim BK
Hong GR
Ko YG
Choi D
Jang Y
Hong MK
Source :
Korean circulation journal [Korean Circ J] 2021 Mar; Vol. 51 (3), pp. 222-231.
Publication Year :
2021

Abstract

Background and Objectives: Transcatheter aortic valve replacement (TAVR) has been reported as a good alternative for surgical aortic valve replacement in patients with small aortic annulus. Head-to-head comparisons of different transcatheter aortic valves in these patients are insufficient. We compared the outcomes after TAVR between two different types of recent transcatheter aortic valves (self-expanding vs. balloon-expandable) in patients with small aortic annulus.<br />Methods: A total of 70 patients with severe aortic stenosis and small annulus (mean diameter ≤23 mm or minimal diameter ≤21 mm on computed tomography) underwent TAVR with either a self-expanding valve with supra-annular location (n=45) or a balloon-expandable valve with intra-annular location (n=25). The echocardiographic hemodynamic parameters after TAVR and 1-year follow-up were compared.<br />Results: Between the self-expanding and balloon-expandable valve-treated patients, the clinical outcomes including permanent pacemaker implantation (11.1% vs. 8.0%), acute kidney injury stage 2 or 3 (4.4% vs. 4.0%), and major vascular complication (4.4% vs. 0.0%) were similar without all-cause mortality, stroke, and life-threatening bleeding during 30-day follow-up. Compared with the balloon-expandable valve-treated patients, the self-expanding valve-treated patients presented larger effective orifice area (EOA) (1.46±0.28 vs. 1.75±0.42 cm², p=0.002) and indexed EOA (0.95±0.21 vs. 1.18±0.28 cm²/m², p=0.001), whereas mean aortic valve gradient (11.7±2.9 vs. 8.9±5.2 mmHg, P=0.005) and incidence of ≥moderate prosthesis-patient mismatch (36.0% vs. 8.9%, p=0.009) were lower. These hemodynamic differences were maintained at 1-year follow-up.<br />Conclusions: TAVR with self-expanding valves was associated with superior hemodynamic outcomes compared with balloon-expandable valves in patients with small aortic annulus.<br />Competing Interests: MK Hong and YG Ko are proctors of Medtronic. The other authors have no financial conflicts of interest.<br /> (Copyright © 2021. The Korean Society of Cardiology.)

Details

Language :
English
ISSN :
1738-5520
Volume :
51
Issue :
3
Database :
MEDLINE
Journal :
Korean circulation journal
Publication Type :
Academic Journal
Accession number :
33655721
Full Text :
https://doi.org/10.4070/kcj.2020.0409