Detection of postlaser vision correction ectasia with a new combined biomechanical index.

Authors :
Vinciguerra R
Ambrósio R Jr
Elsheikh A
Hafezi F
Yong Kang DS
Kermani O
Koh S
Lu N
Padmanabhan P
Roberts CJ
Taneri S
Trattler W
Eliasy A
Jum I
Lopes B
Padmanaban V
Rosetta P
Rost A
Torres-Netto EA
Vinciguerra P
Source :
Journal of cataract and refractive surgery [J Cataract Refract Surg] 2021 Oct 01; Vol. 47 (10), pp. 1314-1318.
Publication Year :
2021

Abstract

Purpose: To validate and evaluate the use of a new biomechanical index known as the Corvis biomechanical index-laser vision correction (CBI-LVC) as a method for separating stable post-LVC eyes from post-LVC eyes with ectasia.<br />Setting: 10 clinics from 9 countries.<br />Design: Retrospective, multicenter, clinical study.<br />Methods: The study was designed with 2 purposes: to develop the CBI-LVC, which combines dynamic corneal response (DCR) parameters provided by a high-speed dynamic Scheimpflug camera (CorVis ST; OCULUS Optikgeräte GmbH) and then to evaluate its ability to detect post-LVC ectasia. The CBI-LVC includes integrated inverse radius, applanation 1 (A1) velocity, A1 deflection amplitude, highest concavity and arclength, deformation amplitude ratio of 2 mm, and A1 arclength in millimeters. Logistic regression with Wald forward stepwise approach was used to identify the optimal combination of DCRs to create the CBI-LVC and then separate stable from LVC-induced ectasia. Eighty percentage of the database was used for training the software and 20% for validation.<br />Results: 736 eyes of 736 patients were included (685 stable LVC and 51 post-LVC ectasia). The receiver operating characteristic curve analysis showed an area under the curve of 0.991 when applying CBI-LVC in the validation dataset and 0.998 in the training dataset. A cutoff of 0.2 was able to separate stable LVC from ectasia with a sensitivity of 93.3% and a specificity of 97.8%.<br />Conclusions: The CBI-LVC was highly sensitive and specific in distinguishing stable from ectatic post-LVC eyes. Using CBI-LVC in routine practice, along with topography and tomography, can aid the early diagnosis of post-LVC ectasia and allow intervention prior to visually compromising progression.<br /> (Copyright © 2021 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of ASCRS and ESCRS.)

Details

Language :
English
ISSN :
1873-4502
Volume :
47
Issue :
10
Database :
MEDLINE
Journal :
Journal of cataract and refractive surgery
Publication Type :
Academic Journal
Accession number :
33769761
Full Text :
https://doi.org/10.1097/j.jcrs.0000000000000629