First multicenter experience using the Silk Vista flow diverter in 60 consecutive intracranial aneurysms: technical aspects.

Authors :
Martínez-Galdámez M
Onal Y
Cohen JE
Kalousek V
Rivera R
Sordo JG
Echeverria D
Pereira VM
Blasco J
Mardighian D
Velioglu M
van Adel B
Wang BH
Gomori JM
Filioglo A
Čulo B
Lynch J
Binboga AB
Onay M
Galvan Fernandez J
Schüller Arteaga M
Guio JD
Bhogal P
Makalanda L
Wong K
Aggour M
Gentric JC
Gavrilovic V
Navia P
Fernandez Prieto A
González E
Aldea J
López JL
Lorenzo-Gorriz A
Madelrieux T
Rouchaud A
Mounayer C
Source :
Journal of neurointerventional surgery [J Neurointerv Surg] 2021 Dec; Vol. 13 (12), pp. 1145-1151. Date of Electronic Publication: 2021 Apr 08.
Publication Year :
2021

Abstract

Background: The aim of this study was to assess the technical success and procedural safety of the new Silk Vista device (SV) by evaluating the intraprocedural and periprocedural complication rate after its use in several institutions worldwide.<br />Methods: The study involved a retrospective review of multicenter data regarding a consecutive series of patients with intracranial aneurysms, treated with the SV between September 2020 and January 2021. Clinical, intra/periprocedural and angiographic data, including approach, materials used, aneurysm size and location, device/s, technical details and initial angiographic aneurysm occlusion, were analyzed.<br />Results: 60 aneurysms were treated with SV in 57 procedures. 66 devices were used, 3 removed and 63 implanted. The devices opened instantaneously in 60 out of 66 (91%) cases and complete wall apposition was achieved in 58 out of 63 (92%) devices implanted. In 4 out of 66 (6%) devices a partial opening of the distal end occurred, and in 5 (8%) devices incomplete apposition was reported. There were 3 (5%) intraprocedural thromboembolic events managed successfully with no permanent neurological morbidity, and 4 (7%) postprocedural events. There was no mortality in this study. The initial occlusion rates in the 60 aneurysms were as follows: O'Kelly-Marotta (OKM) A in 34 (57%) cases, OKM B in 15 (25%) cases, OKM C in 6 (10%) cases, and OKM D in 5 (8%) cases.<br />Conclusions: Our study demonstrated that the use of the new flow diverter Silk Vista for the treatment of intracranial aneurysms is feasible and technically safe.<br />Competing Interests: Competing interests: MMG is proctor and consultant for Balt, Medtronic and Stryker. PG is consultant for Phenox, Balt and Cerenovus. JGF is consultant for Medtronic and Balt. MSA is consultant for Medtronic and Balt. PN is consultant and proctor for Balt, Stryker and Penumbra. The rest of the co-authors have not declared any conflict of interesting regarding this manuscript.<br /> (© Author(s) (or their employer(s)) 2021. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.)

Details

Language :
English
ISSN :
1759-8486
Volume :
13
Issue :
12
Database :
MEDLINE
Journal :
Journal of neurointerventional surgery
Publication Type :
Academic Journal
Accession number :
33832971
Full Text :
https://doi.org/10.1136/neurintsurg-2021-017421