Back to Search
Start Over
Feasibility of semi-recumbent bicycle exercise Doppler echocardiography for the evaluation of the right heart and pulmonary circulation unit in different clinical conditions: the RIGHT heart international NETwork (RIGHT-NET).
- Source :
-
The international journal of cardiovascular imaging [Int J Cardiovasc Imaging] 2021 Jul; Vol. 37 (7), pp. 2151-2167. Date of Electronic Publication: 2021 Apr 18. - Publication Year :
- 2021
-
Abstract
- Exercise Doppler echocardiography (EDE) is a well-validated tool in ischemic and valvular heart diseases. However, its use in the assessment of the right heart and pulmonary circulation unit (RH-PCU) is limited. The aim of this study is to assess the semi-recumbent bicycle EDE feasibility for the evaluation of RH-PCU in a large multi-center population, from healthy individuals and elite athletes to patients with overt or at risk of developing pulmonary hypertension (PH). From January 2019 to July 2019, 954 subjects [mean age 54.2 ± 16.4 years, range 16-96, 430 women] underwent standardized semi-recumbent bicycle EDE with an incremental workload of 25 watts every 2 min, were prospectively enrolled among 7 centers participating to the RIGHT Heart International NETwork (RIGHT-NET). EDE parameters of right heart structure, function and pressures were obtained according to current recommendations. Right ventricular (RV) function at peak exercise was feasible in 903/940 (96%) by tricuspid annular plane systolic excursion (TAPSE), 667/751 (89%) by tissue Doppler-derived tricuspid lateral annular systolic velocity (S') and 445/672 (66.2%) by right ventricular fractional area change (RVFAC). RV-right atrial pressure gradient [RV-RA gradient = 4 × tricuspid regurgitation velocity <superscript>2</superscript> (TRV)] was feasible in 894/954 patients (93.7%) at rest and in 816/954 (85.5%) at peak exercise. The feasibility rate in estimating pulmonary artery pressure improved to more than 95%, if both TRV and/or right ventricular outflow tract acceleration time (RVOT AcT) were considered. In high specialized echocardiography laboratories semi-recumbent bicycle EDE is a feasible tool for the assessment of the RH-PCU pressure and function.<br /> (© 2021. The Author(s), under exclusive licence to Springer Nature B.V.)
Details
- Language :
- English
- ISSN :
- 1875-8312
- Volume :
- 37
- Issue :
- 7
- Database :
- MEDLINE
- Journal :
- The international journal of cardiovascular imaging
- Publication Type :
- Academic Journal
- Accession number :
- 33866467
- Full Text :
- https://doi.org/10.1007/s10554-021-02243-x