False-Positive Axillary Lymph Nodes on FDG PET/CT Resulting From COVID-19 Immunization.
- Source :
-
Clinical nuclear medicine [Clin Nucl Med] 2021 Dec 01; Vol. 46 (12), pp. 1004-1005. - Publication Year :
- 2021
-
Abstract
- Abstract: World-wide mass COVID-19 vaccination has been deployed starting with those most vulnerable, including the elderly and cancer patients. A 70-year-old man with right lung cancer underwent staging FDG PET/CT, which demonstrated an avid right lung mass with avid hilar and mediastinal nodes. Avid left axillary nodes of benign configuration were also noted. The patient had the Oxford-AstraZeneca COVID-19 vaccination in the left arm a week earlier. On reflection, the axillary nodes were concluded to be reactive related to this. This is a potential COVID-19 vaccination associated pitfall on PET/CT that should be considered when interpreting FDG PET/CT images.<br />Competing Interests: Conflicts of interest and sources of funding: none declared.<br /> (Copyright © 2021 Wolters Kluwer Health, Inc. All rights reserved.)