Mimicking Peroxidase-Like Activity of Nitrogen-Doped Carbon Dots (N-CDs) Coupled with a Laminated Three-Dimensional Microfluidic Paper-Based Analytical Device (Laminated 3D-μPAD) for Smart Sensing of Total Cholesterol from Whole Blood.

Authors :
Kitchawengkul N
Prakobkij A
Anutrasakda W
Yodsin N
Jungsuttiwong S
Chunta S
Amatatongchai M
Jarujamrus P
Source :
Analytical chemistry [Anal Chem] 2021 May 11; Vol. 93 (18), pp. 6989-6999. Date of Electronic Publication: 2021 Apr 28.
Publication Year :
2021

Abstract

This work presents a simple hydrothermal synthesis of nitrogen-doped carbon dots (N-CDs), fabrication of microfluidic paper-based analytical device (μPAD), and their joint application for colorimetric determination of total cholesterol (TC) in human blood. The N-CDs were characterized by various techniques including transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), and X-ray powder diffraction (XRD), and the optical and electronic properties of computational models were studied using the time-dependent density functional theory (TD-DFT). The characterization results confirmed the successful doping of nitrogen on the surface of carbon dots. The N-CDs exhibited high affinity toward 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid)-diammonium salt (ABTS) with the Michaelis-Menten constant ( K <subscript>M</subscript> ) of 0.018 mM in a test for their peroxidase-like activity. Particularly, since hydrogen peroxide (H <subscript>2</subscript> O <subscript>2</subscript> ) is the oxidative product of cholesterol in the presence of cholesterol oxidase, a sensitive and selective method of cholesterol detection was developed. Overall, the obtained results from TD-DFT confirm the strong adsorption of H <subscript>2</subscript> O <subscript>2</subscript> on the graphitic N positions of the N-CDs. The laminated three-dimensional (3D)-μPAD featuring a 6 mm circular detection zone was fabricated using a simple wax screen printing technique. Classification of TC according to the clinically relevant criteria (healthy, <5.2 mM; borderline, 5.2-6.2 mM; and high risk, >6.2 mM) could be determined by the naked eye within 10 min by simple comparison using a color chart. Overall, the proposed colorimetric device serves as a low-cost, rapid, simple, sensitive, and selective alternative for TC detection in whole blood samples that is friendly to unskilled end users.

Details

Language :
English
ISSN :
1520-6882
Volume :
93
Issue :
18
Database :
MEDLINE
Journal :
Analytical chemistry
Publication Type :
Academic Journal
Accession number :
33909416
Full Text :
https://doi.org/10.1021/acs.analchem.0c05459