Back to Search Start Over

Parameters of biliary hydrodynamic injection during endoscopic retrograde cholangio-pancreatography in pigs for applications in gene delivery.

Authors :
Huang Y
Kruse RL
Ding H
Itani MI
Morrison J
Wang ZZ
Selaru FM
Kumbhari V
Source :
PloS one [PLoS One] 2021 Apr 28; Vol. 16 (4), pp. e0249931. Date of Electronic Publication: 2021 Apr 28 (Print Publication: 2021).
Publication Year :
2021

Abstract

The biliary system is routinely accessed for clinical purposes via endoscopic retrograde cholangiopancreatography (ERCP). We previously pioneered ERCP-mediated hydrodynamic injection in large animal models as an innovative gene delivery approach for monogenic liver diseases. However, the procedure poses potential safety concerns related mainly to liver or biliary tree injury. Here, we sought to further define biliary hydrodynamic injection parameters that are well-tolerated in a human-sized animal model. ERCP was performed in pigs, and hydrodynamic injection carried out using a novel protocol to reduce duct wall stress. Each pig was subjected to multiple repeated injections to expedite testing and judge tolerability. Different injection parameters (volume, flow rate) and injection port diameters were tested. Vital signs were monitored throughout the procedure, and liver enzyme panels were collected pre- and post-procedure. Pigs tolerated repeated biliary hydrodynamic injections with only occasional, mild, isolated elevation in aspartate aminotransferase (AST), which returned to normal levels within one day post-injection. All other liver tests remained unchanged. No upper limit of volume tolerance was reached, which suggests the biliary tree can readily transmit fluid into the vascular space. Flow rates up to 10 mL/sec were also tolerated with minimal disturbance to vital signs and no anatomic rupture of bile ducts. Measured intrabiliary pressure was up to 150 mmHg, and fluid-filled vesicles were induced in liver histology at high flow rates, mimicking the changes in histology observed in mouse liver after hydrodynamic tail vein injection. Overall, our investigations in a human-sized pig liver using standard clinical equipment suggest that ERCP-guided hydrodynamic injection will be safely tolerated in patients. Future investigations will interrogate if higher flow rates and pressure mediate higher DNA delivery efficiencies.<br />Competing Interests: Conflict of Interest: R.L.K, Y.H., V.K., and F.M.S. have a patent application filed on the work. All other authors do not have conflict of interests. There are no other licensing or consulting interests; this does not alter our adherence to PLOS ONE policies on sharing data and materials.

Details

Language :
English
ISSN :
1932-6203
Volume :
16
Issue :
4
Database :
MEDLINE
Journal :
PloS one
Publication Type :
Academic Journal
Accession number :
33909609
Full Text :
https://doi.org/10.1371/journal.pone.0249931