Back to Search
Start Over
Four-year results of the Bolton relay proximal scallop endograft in the management of thoracic and thoracoabdominal aortic pathology with unfavorable proximal landing zone.
- Source :
-
Journal of vascular surgery [J Vasc Surg] 2021 Nov; Vol. 74 (5), pp. 1447-1455. Date of Electronic Publication: 2021 Apr 30. - Publication Year :
- 2021
-
Abstract
- Background: Thoracic endovascular aortic repair with a scallop design (scallop-TEVAR) is a useful treatment strategy to extend the proximal landing zone (PLZ), while maintaining perfusion to one or more of the supra-aortic trunks (SATs) when treating aortic pathology with an unfavorable PLZ. The durability of this approach with the Bolton Relay scallop endograft (Terumo Aortic, Sunrise, Fla) has not been established.<br />Methods: A retrospective review of prospectively collected data on consecutive patients that received scallop-TEVAR in zones 0 to 2 at a tertiary aortic unit was undertaken. The main outcome was durability, characterized by survival estimates, freedom from reintervention to the thoracic aorta and PLZ, migration and aneurysm sac regression.<br />Results: Between 2009 and 2019, 38 patients (71% male; median age, 70 years) underwent scallop-TEVAR for thoracic aortic pathology (n = 28, 74%) or as a part of thoracoabdominal aneurysm repair (n = 10 [26%]). The use of scallop-TEVAR significantly extended the PLZ (median, 5 mm preoperative PLZ vs 26 mm extended PLZ; P = .0001). A total of 41 SATs were perfused with a scallop, including the left subclavian artery (n = 25), left common carotid artery (n = 6), neo/innominate artery (n = 4), left subclavian artery, and vertebral artery (n = 1), innominate artery, and left common carotid artery (n = 2) in conjunction with 15 extra-anatomical bypasses. The PLZ was at Ishimaru zone 0 and 1 in 6 cases (16%), respectively, and zone 2 in 26 cases (68%). Technical success was 98%. The 30-day mortality was 5% (2/38; 1 death from myocardial infarction and 1 from multiorgan failure). A minor stroke occurred in three patients (8%) and temporary spinal cord ischemia in two patients (5%). The median follow-up was 4.5 years (range, 0-10.53 years) during which two patients (5%) developed type Ia endoleak and required intervention to the PLZ (one from device-related migration and one from disease progression). All-cause and aorta-related survival were 72% and 85% and freedom from thoracic and PLZ reintervention was 92% and 97%, respectively. There were no cases of early or late thoracic aortic rupture, retrograde type A aortic dissection or SAT occlusion.<br />Conclusions: Scallop-TEVAR offers a less invasive treatment option to extend the seal zone in selected patients with an unfavorable PLZ, allowing for a durable repair in terms of overall survival and reintervention. Periprocedural stroke remains a principle concern.<br /> (Copyright © 2021 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.)
- Subjects :
- Adult
Aged
Aged, 80 and over
Aortic Aneurysm, Thoracic diagnostic imaging
Aortic Aneurysm, Thoracic mortality
Blood Vessel Prosthesis Implantation adverse effects
Blood Vessel Prosthesis Implantation mortality
Databases, Factual
Endovascular Procedures adverse effects
Endovascular Procedures mortality
Female
Humans
London
Male
Middle Aged
Postoperative Complications etiology
Prosthesis Design
Retrospective Studies
Risk Assessment
Risk Factors
Time Factors
Treatment Outcome
Aortic Aneurysm, Thoracic surgery
Blood Vessel Prosthesis
Blood Vessel Prosthesis Implantation instrumentation
Endovascular Procedures instrumentation
Subjects
Details
- Language :
- English
- ISSN :
- 1097-6809
- Volume :
- 74
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- Journal of vascular surgery
- Publication Type :
- Academic Journal
- Accession number :
- 33940076
- Full Text :
- https://doi.org/10.1016/j.jvs.2021.04.027