Back to Search Start Over

Dapsone-induced methemoglobinemia-A case report.

Authors :
Kabir H
Lakshmanan R
Gopinath S
Bhonagiri D
Source :
Clinical case reports [Clin Case Rep] 2021 May 05; Vol. 9 (5), pp. e04054. Date of Electronic Publication: 2021 May 05 (Print Publication: 2021).
Publication Year :
2021

Abstract

Dapsone therapy is associated with methemoglobinemia. Pulse oximetry is used to indicate adequate oxygen saturations, and co-oximetry is needed to diagnose low arterial oxygen saturations. Clinicians should aware while prescribing dapsone.<br />Competing Interests: None of the authors have any conflict of interest.<br /> (© 2021 The Authors. Clinical Case Reports published by John Wiley & Sons Ltd.)