Back to Search
Start Over
Mid-term Outcome of the Edge-To-Edge Mitral Valve Repair Via Aortic Outflow Tract in High-Risk Patients.
- Source :
-
Seminars in thoracic and cardiovascular surgery [Semin Thorac Cardiovasc Surg] 2022 Summer; Vol. 34 (2), pp. 512-516. Date of Electronic Publication: 2021 Jun 02. - Publication Year :
- 2022
-
Abstract
- The edge-to-edge mitral valve repair technique, invented by Alfieri and colleagues, introduced valve repair as a treatment option for patients with complex diseases where standard annuloplasty and related repair techniques are insufficient, due to annular calcification and patient frailty. We retrospectively evaluated the results of a transaortic edge-to-edge mitral valve repair (Alfieri stitch) in high-risk patients who were undergoing aortic valve replacement. From February, 2012 to December, 2017, 43 patients underwent transaortic edge-to-edge mitral valve repair with concomitant aortic valve replacement at a single institution. Preoperative and postoperative echocardiograms were compared. Home telephone follow up was conducted and postoperative morbidity was examined, including the need for reoperation, stroke and cardiac arrhythmia. 30-day and long-term survival rates were also determined. Mitral regurgitation (MR) was graded semi-quantitatively as 0 (trace and/or none), mild (1), moderate (2) or moderate to severe (3-4). The patients were 74 ± 7.8 years old. 65% of the patients were male. Mean cardiopulmonary bypass time was 115 ± 37 minutes and mean cross-clamp time was 71 ± 23 minutes. There was a significant improvement in preoperative vs postoperative median MR grade (2 (IQR 2-3) vs 0 (IQR 0-1); P = 0.05). Follow-up transthoracic echocardiograms in 29 patients obtained at a median of 9 months' (range 3 - 19 months') and in 16 patients at a median of 34 months' postoperatively (range 21 - 53 months') showed mild (1 (IQR 1-2)) grade of mitral regurgitation. 30-day survival was 98%. Long term survival at 12 and 24 months' were 88% and 81% respectively. Mitral valve reoperation was conducted in 1 patient (2%), who was suffering of endocarditis. Stroke occurred in 2 patients (7%). Cardiac arrhythmia was observed in 15 patients (35%). 8 patients (19%) suffered from atrial fibrillation and 7 patients (16%) displayed atrioventricular blockage. 10 patients (23%) could be treated conservatively and 5 patients (12%) needed implantation of a pacemaker. Transaortic edge-to-edge mitral valve repair can be safely performed during aortic valve replacement in high-risk patients and improves even long-term MR grade. Postoperative cardiac arrhythmia occurs frequently. 66% of them could be treated successfully by conservative procedures.<br /> (Copyright © 2021. Published by Elsevier Inc.)
- Subjects :
- Aged
Aged, 80 and over
Female
Humans
Male
Mitral Valve diagnostic imaging
Mitral Valve surgery
Retrospective Studies
Treatment Outcome
Heart Valve Prosthesis Implantation adverse effects
Heart Valve Prosthesis Implantation methods
Mitral Valve Annuloplasty adverse effects
Mitral Valve Annuloplasty methods
Mitral Valve Insufficiency diagnostic imaging
Mitral Valve Insufficiency surgery
Stroke
Subjects
Details
- Language :
- English
- ISSN :
- 1532-9488
- Volume :
- 34
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Seminars in thoracic and cardiovascular surgery
- Publication Type :
- Academic Journal
- Accession number :
- 34089830
- Full Text :
- https://doi.org/10.1053/j.semtcvs.2021.05.001