Back to Search Start Over

Aortic angle distribution and predictors of horizontal aorta in patients undergoing transcatheter aortic valve replacement.

Authors :
Moscarelli M
Gallo F
Gallone G
Kim WK
Reifart J
Veulemans V
Zeus T
Toggweiler S
De Backer O
Søndergaard L
Mangieri A
De Marco F
Regazzoli D
Reimers B
Muntané-Carol G
Lauriero RE
Armario X
Mylotte D
Bhadra OD
Conradi L
Donday LAM
Nombela-Franco L
Barbanti M
Reddavid C
Brugaletta S
Nicolini E
Tzanis G
Rodes-Cabau J
Colombo A
Giannini F
Source :
International journal of cardiology [Int J Cardiol] 2021 Sep 01; Vol. 338, pp. 58-62. Date of Electronic Publication: 2021 Jun 06.
Publication Year :
2021

Abstract

Background: Horizontal aorta (HA) is an anatomical feature that can pose significant technical challenges for the successful positioning of the bioprosthetic valve during transcatheter aortic valve replacement (TAVR). Physiological range of aortic angle (AA) is unknown; hence there is no cutoff AA for classifying HA. Moreover, patient characteristics predicting HA are under-investigated.<br />Methods: This was a retrospective analysis of prospective collected data from 16 heart valve centers in Europe. The study utilized a common dataset with a priori agreed-upon definitions and variables. Eligible patients underwent TAVR between 2014 and 2020 and had multidetector computed tomographic imaging data available for determining the AA. The analysis described the distribution of AA and potential predictors of HA. Inter-center variability was also explored.<br />Results: For 4022 patients analyzed, the mean AA ± standard deviation was 49.4° ± 9.4° (median 49°, inter-quartile range [IQR] 12°, range 18-90°). There was no significant difference in mean AA between men and women (49.4° ± 9.1° vs. 49.6° ± 9.3°, respectively; p = 0.53); therefore, 49.4° was accepted as the cutoff value for HA in subsequent analyses. Covariates significantly associated with HA included age (odds ratio [OR]: 1.02, 95% confidence interval [CI]: 1.01-1.04, p < 0.001), body mass index (OR: 1.06, 95% CI: 1.05-1.08, p < 0.01), previous cardiac surgery (OR: 0.58, 95% CI: 0.45-0.75, p < 0.001), and porcelain aorta (OR: 0.66, 95% CI: 0.52-0.85, p = 0.001). Some inter-center variability was observed.<br />Conclusions: We defined 49.4° as the mean AA, and also associated predictors of HA in a large case series of patients with severe aortic stenosis candidates for TAVR.<br />Competing Interests: Declaration of Competing Interest None.<br /> (Copyright © 2021 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1874-1754
Volume :
338
Database :
MEDLINE
Journal :
International journal of cardiology
Publication Type :
Academic Journal
Accession number :
34090956
Full Text :
https://doi.org/10.1016/j.ijcard.2021.05.054