Back to Search Start Over

A ratiometric electrochemical sensor for selectively monitoring monoamine oxidase A in the live brain.

Authors :
Zhang C
Tang C
Mei Y
Zhang L
Zhu A
Tian Y
Source :
Chemical communications (Cambridge, England) [Chem Commun (Camb)] 2021 Jul 07; Vol. 57 (53), pp. 6487-6490. Date of Electronic Publication: 2021 Jun 08.
Publication Year :
2021

Abstract

Herein, an electrochemical method for selectively sensing and accurately quantifying monoamine oxidase A (MAO-A) in the cortex and thalamus of a live mouse brain was reported. Using this tool, it was found that MAO-A increased Ca <superscript>2+</superscript> entry into neurons via the TPRM2 channel in the live mouse brain of an AD model.

Details

Language :
English
ISSN :
1364-548X
Volume :
57
Issue :
53
Database :
MEDLINE
Journal :
Chemical communications (Cambridge, England)
Publication Type :
Academic Journal
Accession number :
34100043
Full Text :
https://doi.org/10.1039/d1cc00787d