Back to Search Start Over

The Impact of Aortic Angulation on Contemporary Transcatheter Aortic Valve Replacement Outcomes.

Authors :
Medranda GA
Musallam A
Zhang C
Rappaport H
Gallino PE
Case BC
Satler LF
Ben-Dor I
Rogers T
Waksman R
Source :
JACC. Cardiovascular interventions [JACC Cardiovasc Interv] 2021 Jun 14; Vol. 14 (11), pp. 1209-1215.
Publication Year :
2021

Abstract

Objectives: The aim of this study was to investigate whether the degree of aortic angulation (AA) affects outcomes after transcatheter aortic valve replacement (TAVR) using newer-generation transcatheter heart valves (THVs).<br />Background: AA ≥48° has been reported to adversely influence accurate THV deployment, procedural success, fluoroscopy time, and paravalvular leak (PVL) in patients undergoing TAVR with early generation self-expanding (SE) THVs.<br />Methods: A retrospective observational study was conducted among 841 patients across all risk strata who underwent transfemoral TAVR using the balloon-expandable (BE) SAPIEN 3 or the SE CoreValve Evolut PRO from 2015 to 2020. The previously published cutoff of 48° was used to analyze procedural success and in-hospital outcomes according to THV type. Receiver-operating characteristic analysis was performed to investigate the impact of AA on an in-hospital composite outcome (need for >1 THV, more than mild PVL, new permanent pacemaker implantation, stroke, and death).<br />Results: AA ≥48° did not influence outcomes in patients with BE THVs. Additionally, AA ≥48° did not influence procedural success (99.1% vs. 99.1%; p = 0.980), number of THVs used (1.02 vs. 1.04; p = 0.484), rates of more than mild PVL (0.4% vs. 0%; p = 0.486), new permanent pacemaker implantation (11.8% vs. 17.1%; p = 0.178), in-hospital stroke (3.9% vs. 1.8%; p = 0.298), or in-hospital death (0.4% vs. 0.9%; p = 0.980) in patients with SE THVs. Receiver-operating characteristic analysis demonstrated similar outcomes irrespective of AA, with areas under the curve of 0.5525 for SE THVs and 0.5115 for BE THVs.<br />Conclusions: AA no longer plays a role with new-generation BE or SE THVs in contemporary TAVR practice. AA ≥48° did not affect procedural success or in-hospital outcomes and should no longer be a consideration when determining THV selection.<br />Competing Interests: Funding Support and Author Disclosures Dr. Rogers is a proctor and consultant for Medtronic and Edwards Lifesciences; is an advisory board member for Medtronic; and holds equity interest in Transmural Systems. Dr. Waksman is an advisory board member for Abbott Vascular, Amgen, Boston Scientific, Cardioset, Cardiovascular Systems, Medtronic, Philips, and Pi-Cardia; is a consultant for Abbott Vascular, Amgen, Biotronik, Boston Scientific, Cardioset, Cardiovascular Systems, Medtronic, Philips, Pi-Cardia, and Transmural Systems; has received grant support from AstraZeneca, Biotronik, Boston Scientific, and Chiesi; is a Speakers Bureau member for AstraZeneca and Chiesi; and is an investor in MedAlliance and Transmural Systems. All other authors have reported that they have no relationships relevant to the contents of this paper to disclose.<br /> (Copyright © 2021. Published by Elsevier Inc.)

Details

Language :
English
ISSN :
1876-7605
Volume :
14
Issue :
11
Database :
MEDLINE
Journal :
JACC. Cardiovascular interventions
Publication Type :
Academic Journal
Accession number :
34112456
Full Text :
https://doi.org/10.1016/j.jcin.2021.03.027