Feasibility of late acquisition [68Ga]Ga-PSMA-11 PET/CT using a long axial field-of-view PET/CT scanner for the diagnosis of recurrent prostate cancer-first clinical experiences.

Authors :
Alberts I
Prenosil G
Mingels C
Bohn KP
Viscione M
Sari H
Rominger A
Afshar-Oromieh A
Source :
European journal of nuclear medicine and molecular imaging [Eur J Nucl Med Mol Imaging] 2021 Dec; Vol. 48 (13), pp. 4456-4462. Date of Electronic Publication: 2021 Jun 21.
Publication Year :
2021

Abstract

Purpose: While acquisition of images in [ <superscript>68</superscript>  Ga]Ga-PSMA-11 following longer uptake times can improve lesion uptake and contrast, resultant imaging quality and count statistics are limited by the isotope's half-life (68 min). Here, we present a series of cases demonstrating that when performed using a long axial field-of-view (LAFOV) PET/CT system, late imaging is feasible and can even provide improved image quality compared to regular acquisitions.<br />Methods: In this retrospective case series, we report our initial experiences with 10 patients who underwent standard imaging at 1 h p.i. following administration of 192 ± 36 MBq [ <superscript>68</superscript>  Ga]Ga-PSMA-11 with additional late imaging performed at 4 h p.i. Images were acquired in a single bed position for 6 min at 1 h p.i. and 16 min p.i. at 4 h p.i. using a LAFOV scanner (106 cm axial FOV). Two experienced nuclear medicine physicians reviewed all scans in consensus and evaluated overall image quality (5-point Likert scale), lesion uptake in terms of standardised uptake values (SUV), tumour to background ratio (TBR) and target-lesion signal to background noise (SNR).<br />Results: Subjective image quality as rated on a 5-point Likert scale was only modestly lower for late acquisitions (4.2/5 at 4 h p.i.; 5/5 1 h p.i.), TBR was significantly improved (4 h: 3.41 vs 1 h: 1.93, p < 0.001) and SNR was improved with borderline significance (4 h: 33.02 vs 1 h: 24.80, p = 0.062) at later imaging. Images were obtained with total acquisition times comparable to routine examinations on standard axial FOV scanners.<br />Conclusion: Late acquisition in tandem with a LAFOV PET/CT resulted in improvements in TBR and SNR and was associated with only modest impairment in subjective visual imaging quality. These data show that later acquisition times for [ <superscript>68</superscript>  Ga]Ga-PSMA-11 may be preferable when performed on LAFOV systems.<br /> (© 2021. The Author(s).)

Details

Language :
English
ISSN :
1619-7089
Volume :
48
Issue :
13
Database :
MEDLINE
Journal :
European journal of nuclear medicine and molecular imaging
Publication Type :
Academic Journal
Accession number :
34155538
Full Text :
https://doi.org/10.1007/s00259-021-05438-5