Back to Search Start Over

Utility of Radial Probe Endobronchial Ultrasound Guided Transbronchial Lung Biopsy in Bronchus Sign Negative Peripheral Pulmonary Lesions.

Authors :
Hong KS
Lee KH
Chung JH
Shin KC
Jin HJ
Jang JG
Ahn JH
Source :
Journal of Korean medical science [J Korean Med Sci] 2021 Jun 21; Vol. 36 (24), pp. e176. Date of Electronic Publication: 2021 Jun 21.
Publication Year :
2021

Abstract

Background: The presence of the bronchus sign on chest computed tomography is associated with an increased diagnostic yield of radial probe endobronchial ultrasound-guided transbronchial lung biopsy (RP-EBUS-TBLB). However, the utility of RP-EBUS-TBLB for bronchus sign negative peripheral pulmonary lesions (PPLs) remains unknown. We investigated the utility of RP-EBUS-TBLB in bronchus sign negative PPLs.<br />Methods: We retrospectively reviewed data from 109 patients who underwent RP-EBUS for bronchus sign negative PPLs from January 2019 to August 2020. TBLB was performed using RP-EBUS with a guide sheath and without fluoroscopy. The EBUS visualization and TBLB diagnostic yields were assessed. Multivariable logistic regression analyses were used to identify factors affecting the EBUS visualization and diagnostic yields.<br />Results: The EBUS visualization yield was 74.1% (68/109). Of the 109 lung lesions, 92 were definitively diagnosed. The overall diagnostic accuracy, sensitivity, specificity, positive predictive value, and negative predictive value were 50.5% (55/109), 34.9% (29/83), 100% (26/26), 100% (29/29), and 32.5% (26/80), respectively. In multivariable analyses, the size of the lesion (≥ 20 mm; odds ratio [OR], 2.62; 95% confidence interval [CI], 1.16-5.93; P = 0.021) and the distance from the pleura (> 10 mm; OR, 2.37; 95% CI, 1.02-5.52; P = 0.045) were associated with EBUS visualization. Regarding diagnostic yield, having the probe within the lesion (OR, 28.50; 95% CI, 6.26-129.85; P < 0.001) and a solid lesion (OR, 14.58; 95% CI, 2.64-80.38; P = 0.002) were associated with diagnostic success. Pneumothorax and hemoptysis occurred in 3.7% (4/109) and 0.9% (1/109), respectively, of the patients.<br />Conclusion: RP-EBUS-TBLB using a GS can be considered a diagnostic method in bronchus sign negative solid PPLs. Having the probe within the lesion and a solid lesion were important for diagnostic success. Complication rates were acceptable.<br />Competing Interests: The authors have no potential conflicts of interest to disclose.<br /> (© 2021 The Korean Academy of Medical Sciences.)

Details

Language :
English
ISSN :
1598-6357
Volume :
36
Issue :
24
Database :
MEDLINE
Journal :
Journal of Korean medical science
Publication Type :
Academic Journal
Accession number :
34155838
Full Text :
https://doi.org/10.3346/jkms.2021.36.e176