Back to Search Start Over

Modular dual mobility total hip arthroplasty is a viable option for young, active patients : a mid-term follow-up study.

Authors :
Lawrie CM
Barrack RL
Nunley RM
Source :
The bone & joint journal [Bone Joint J] 2021 Jul; Vol. 103-B (7 Supple B), pp. 73-77.
Publication Year :
2021

Abstract

Aims: Dual mobility (DM) implants have been shown to reduce the dislocation rate after total hip arthroplasty (THA), but there remain concerns about the use of cobalt chrome liners inserted into titanium shells. The aim of this study was to assess the clinical outcomes, metal ion levels, and periprosthetic femoral bone mineral density (BMD) at mid-term follow-up in young, active patients receiving a modular DM THA.<br />Methods: This was a prospective study involving patients aged < 65 years, with a BMI of < 35 kg/m <superscript>2</superscript> , and University of California, Los Angeles activity score of > 6 who underwent primary THA with a modular cobalt chrome acetabular liner, highly cross-linked polyethylene mobile bearing, and a cementless titanium femoral stem. Patient-reported outcome measures, whole blood metal ion levels (μg/l), and periprosthetic femoral BMD were measured at baseline and at one, two, and five years postoperatively. The results two years postoperatively for this cohort have been previously reported.<br />Results: A total of 43 patients were enrolled. At minimum follow-up of five years, 23 (53.4%) returned for clinical and radiological review, 25 (58.1%) had metal ion analysis performed, 19 (44.2%) underwent dual energy x-ray absorptiometry scans, and 25 (58%) completed a pain-drawing questionnaire. The mean modified Harris Hip Scores improved significantly from 54.8 (SD 19) preoperatively to 93.08 (SD 10.5) five years postoperatively (p < 0.001). One patient was revised for aseptic acetabular loosening. The mean cobalt levels increased from 0.065 μg/l (SD 0.03) to 0.08 (SD 0.05) and the mean titanium levels increased from 0.35 (SD 0.13) to 0.78 (SD 0.29). The femoral BMD ratio decreased in Gruen Zone 1 (91.9%) at five years postoperatively compared with the baseline scores at six weeks potoperatively. The femoral BMD ratio was maintained in Gruen zones 2 to 7.<br />Conclusion: The use of a modular DM component and a cementless, tapered femoral stem shows excellent mid-term survivorship with minimal concerns for corrosion and metal ion release in a cohort of young, active patients undergoing primary THA. Cite this article: Bone Joint J  2021;103-B(7 Supple B):73-77.

Details

Language :
English
ISSN :
2049-4408
Volume :
103-B
Issue :
7 Supple B
Database :
MEDLINE
Journal :
The bone & joint journal
Publication Type :
Academic Journal
Accession number :
34192909
Full Text :
https://doi.org/10.1302/0301-620X.103B7.BJJ-2021-0145.R1