Back to Search Start Over

Stress Echocardiography After Mitral Valve Repair Using a Semirigid Partial Band.

Authors :
Yamazaki S
Doi K
Numata S
Yamano T
Yamano M
Teramukai S
Yaku H
Source :
The Annals of thoracic surgery [Ann Thorac Surg] 2022 Jul; Vol. 114 (1), pp. 126-132. Date of Electronic Publication: 2021 Sep 01.
Publication Year :
2022

Abstract

Background: The reduction in exercise capacity after mitral valve repair (MVr) for severe degenerative mitral regurgitation is an unsolved issue. This study aimed to evaluate hemodynamics after MVr using a partial semirigid band during exercise stress echocardiography and to identify predictive factors for achieving better exercise capacity after MVr.<br />Methods: We retrospectively analyzed 48 patients using exercise stress echocardiography within 5 years of having undergone MVr using a partial semirigid band between 2013 and 2019. Values of maximal workload were converted into numbers of metabolic equivalents (METs) achieved for each patient. Age and sex expected METs (eMETs) were obtained, and percent eMETs (%eMETs [achieved METs / eMETs × 100]) were calculated. Multivariable linear regression analysis was used to identify the determinants of %eMETs.<br />Results: Only one third of patients achieved eMETs. Significant determinants of %eMETs were age at exercise stress echocardiography (β coefficient 0.64; 95% confidence interval, 0.31 to 0.96; P < .001), female sex (β coefficient 16.9; 95% confidence interval, 8.58 to 25.17; P < .001), and larger indexed device size (device size/body surface area; β coefficient 4.10; 95% confidence interval, 1.74 to 6.46; P = .001). Receiver-operating characteristic curve analysis revealed that a cutoff value of 19.5 mm/m <superscript>2</superscript> or greater indexed device size was optimal for achieving %eMETs greater than 100%, with a sensitivity and specificity of 87% and 79%, respectively.<br />Conclusions: Patients with larger indexed device size achieved greater exercise capacity after MVr using a partial semirigid band. Preoperative evaluation to decide whether we can use an annuloplasty device larger than 19.5 mm/m <superscript>2</superscript> may be important for patients who intend to exercise with high intensity.<br /> (Copyright © 2022 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.)

Details

Language :
English
ISSN :
1552-6259
Volume :
114
Issue :
1
Database :
MEDLINE
Journal :
The Annals of thoracic surgery
Publication Type :
Academic Journal
Accession number :
34480894
Full Text :
https://doi.org/10.1016/j.athoracsur.2021.07.090