Back to Search Start Over

Computational study for temperature distribution in ArF excimer laser corneal refractive surgeries using different beam delivery techniques.

Authors :
Gokul KC
Kandel H
Valiño L
Kaiti R
Roy P
Sohail M
Gurung DB
Source :
Lasers in medical science [Lasers Med Sci] 2022 Apr; Vol. 37 (3), pp. 1709-1716. Date of Electronic Publication: 2021 Sep 26.
Publication Year :
2022

Abstract

Refractive errors are the most common causes of vision impairment worldwide and laser refractive surgery is one of the most frequently performed ocular surgeries. Clinical studies have reported that approximately 10.5% of patients need an additional procedure after the surgery. The major complications of laser surgery are over/under correction and dry eye. An increase in temperature may be a cause for these complications. The purpose of this study was to estimate the increase in temperature during laser refractive surgery and its relationship with the complications observed for different surgical techniques. In this paper, a finite element model was applied to investigate the temperature distribution of the cornea when subjected to ArF excimer laser at a single spot using various beam delivery systems (broad beam, scanning slit, and flying spot). The Pennes bio-heat equation was used to predict the temperature values at different laser pulse energies and frequencies. The maximum temperature increase by ArF laser ([Formula: see text] frequency and [Formula: see text] pulse energy) at a single spot was [Formula: see text] for [Formula: see text] diopter correction ([Formula: see text] of ablation of corneal stroma) using broad beam, scanning slit, and flying spot beam delivery approaches respectively. The peak temperature due to a single pulse was estimated to be [Formula: see text]. Although the peak temperature (sufficient energy to break intermolecular bonds) exists for a very short time ([Formula: see text]) compared to the thermal relaxation time ([Formula: see text]), there is some thermal energy exchange between corneal tissues during a laser refractive surgery. Heating may cause collagen denaturation, collagen shrinkage, and more evaporation and hence proposed to be a risk factor for over/under correction and dry eye.<br /> (© 2021. The Author(s), under exclusive licence to Springer-Verlag London Ltd., part of Springer Nature.)

Details

Language :
English
ISSN :
1435-604X
Volume :
37
Issue :
3
Database :
MEDLINE
Journal :
Lasers in medical science
Publication Type :
Academic Journal
Accession number :
34564765
Full Text :
https://doi.org/10.1007/s10103-021-03420-z