Back to Search
Start Over
Vitreoretinal Lymphoma: Optimizing Diagnostic Yield and Accuracy.
- Source :
-
American journal of ophthalmology [Am J Ophthalmol] 2022 Apr; Vol. 236, pp. 120-129. Date of Electronic Publication: 2021 Oct 06. - Publication Year :
- 2022
-
Abstract
- Purpose: To determine whether the addition of adjunctive tests, including immunohistochemistry (IHC), cytokine analysis, flow cytometry, and IgH gene rearrangement testing, achieves improved diagnostic parameters compared with cytologic smears alone in the detection of vitreoretinal lymphoma (VRL). To determine which of these tests or combination of tests provide the greatest diagnostic utility.<br />Design: Retrospective review to assess diagnostic value.<br />Methods: This single university-affiliated tertiary care center study included data from 237 vitreous biopsies performed between 1999 and 2017 in patients with suspected VRL. From 1999 to 2008-2009, cytologic smears were the sole test performed (84 cases). The protocol initiated in 2008-2009 added the 4 additional diagnostic tests (153 cases). The sensitivity, specificity, positive predictive value, negative predictive value, diagnostic accuracy, and diagnostic yield were calculated. Parameters were calculated for tests individually, for all 5 combined, and all possible 2-, 3-, and 4-test combinations. For cytologic smears, diagnostic parameters were calculated both before and after the addition of adjunctive tests to our protocol and for the entire cohort.<br />Results: Of the 237 vitreous biopsies, 50 samples (21%) were from patients with confirmed central nervous system lymphoma and/or actively treated central nervous system, systemic, or intraocular lymphoma. Diagnostic yields (95% CI) were 90% (85%-93%) for smears, 82% (72%-89%) for IHC, 91% (85%-96%) for cytokine analysis, 76% (67%-84%) for IgH gene rearrangement, and 50% (40%-60%) for flow cytometry. For smears, the sensitivity pre-protocol was 73% (39%-94%), compared with 87% (69%-96%) post-protocol. IgH gene rearrangement was the only test exhibiting low sensitivity (40%). The combination of smears, IHC, and cytokine analysis exhibited the highest diagnostic parameters, with sensitivity 92%, specificity 98%, and diagnostic yield 100%.<br />Conclusions: The combination of cytologic smears, IHC, and cytokine analysis seems to be a reasonable and sufficient protocol for the diagnosis of suspected VRL. IgH gene rearrangement and flow cytometry may be the most expendable tests from our protocol.<br /> (Copyright © 2021 Elsevier Inc. All rights reserved.)
Details
- Language :
- English
- ISSN :
- 1879-1891
- Volume :
- 236
- Database :
- MEDLINE
- Journal :
- American journal of ophthalmology
- Publication Type :
- Academic Journal
- Accession number :
- 34626574
- Full Text :
- https://doi.org/10.1016/j.ajo.2021.09.032