Back to Search Start Over

Feasibility and efficacy of transcatheter interatrial shunt devices for chronic heart failure: a systematic review and meta-analysis.

Authors :
Lauder L
Pereira TV
Degenhardt MC
Ewen S
Kulenthiran S
Coats AJS
Böhm M
Anker SD
da Costa BR
Mahfoud F
Source :
European journal of heart failure [Eur J Heart Fail] 2021 Nov; Vol. 23 (11), pp. 1960-1970. Date of Electronic Publication: 2021 Nov 05.
Publication Year :
2021

Abstract

Aims: To assess the feasibility and efficacy of interatrial shunt devices (IASD) for the treatment of chronic heart failure (CHF).<br />Methods and Results: MEDLINE and the Cochrane Central Register of Controlled Trials from inception until April 2021 were searched for prospective studies investigating dedicated transcatheter IASD for the treatment of CHF. Standardised mean differences were calculated for the within-group changes before and after implantation of the IASD. The pre-defined primary outcome was change in 6-min walking distance (6MWD) from baseline to 12 months. Other outcomes were change in New York Heart Association class, health-related quality of life (HRQoL), echocardiographic and haemodynamic data, device performance and safety. Subgroup analyses were crude univariable meta-regression analyses. Six studies (five single-arm open-label studies, one sham-controlled trial) were included. In these, 226 patients underwent IASD implantation using four different devices. From baseline to 12 months, 6MWD increased by 28.1 m [95% confidence interval (CI) 10.9-45.3] with no evidence for a difference between devices (P for interaction = 0.66) and patients with left ventricular ejection fraction (LVEF) >40% or ≤40% (P for interaction = 0.21). At 12 months, HRQoL improved by 17.7 points (95% CI 10.8-24.6) and pulmonary capillary wedge pressure (PCWP) decreased by 2.0 mmHg (95% CI -3.6 to -0.4). There were no changes in LVEF or N-terminal pro brain natriuretic peptide during follow-up. Shunt patency ranged from 50% for the first-generation v-Wave to 100% for the Corvia IASD II and the second-generation v-Wave system, respectively. The summary risk of serious adverse device-related effects was 8% (95% CI 1-20) at 12 months.<br />Conclusions: Interatrial shunt device implantation in CHF is feasible and associates with improved submaximal exercise capacity (measured by 6MWD) and HRQoL, and reductions in PCWP.<br /> (© 2021 The Authors. European Journal of Heart Failure published by John Wiley & Sons Ltd on behalf of European Society of Cardiology.)

Details

Language :
English
ISSN :
1879-0844
Volume :
23
Issue :
11
Database :
MEDLINE
Journal :
European journal of heart failure
Publication Type :
Academic Journal
Accession number :
34628706
Full Text :
https://doi.org/10.1002/ejhf.2360