Back to Search Start Over

Characterization of inverted coaxial 76 Ge detectors in GERDA for future double- β decay experiments.

Authors :
Agostini M
Araujo G
Bakalyarov AM
Balata M
Barabanov I
Baudis L
Bauer C
Bellotti E
Belogurov S
Bettini A
Bezrukov L
Biancacci V
Bossio E
Bothe V
Brudanin V
Brugnera R
Caldwell A
Cattadori C
Chernogorov A
Comellato T
D'Andrea V
Demidova EV
Marco ND
Doroshkevich E
Fischer F
Fomina M
Gangapshev A
Garfagnini A
Gooch C
Grabmayr P
Gurentsov V
Gusev K
Hakenmüller J
Hemmer S
Hofmann W
Huang J
Hult M
Inzhechik LV
Janicskó Csáthy J
Jochum J
Junker M
Kazalov V
Kermaïdic Y
Khushbakht H
Kihm T
Kirpichnikov IV
Klimenko A
Kneißl R
Knöpfle KT
Kochetov O
Kornoukhov VN
Krause P
Kuzminov VV
Laubenstein M
Lindner M
Lippi I
Lubashevskiy A
Lubsandorzhiev B
Lutter G
Macolino C
Majorovits B
Maneschg W
Manzanillas L
Miloradovic M
Mingazheva R
Misiaszek M
Moseev P
Müller Y
Nemchenok I
Pandola L
Pelczar K
Pertoldi L
Piseri P
Pullia A
Ransom C
Rauscher L
Riboldi S
Rumyantseva N
Sada C
Salamida F
Schönert S
Schreiner J
Schütt M
Schütz AK
Schulz O
Schwarz M
Schwingenheuer B
Selivanenko O
Shevchik E
Shirchenko M
Shtembari L
Simgen H
Smolnikov A
Stukov D
Vasenko AA
Veresnikova A
Vignoli C
von Sturm K
Wester T
Wiesinger C
Wojcik M
Yanovich E
Zatschler B
Zhitnikov I
Zhukov SV
Zinatulina D
Zschocke A
Zsigmond AJ
Zuber K
Zuzel G
Source :
The European physical journal. C, Particles and fields [Eur Phys J C Part Fields] 2021; Vol. 81 (6), pp. 505. Date of Electronic Publication: 2021 Jun 07.
Publication Year :
2021

Abstract

Neutrinoless double- β decay of 76 Ge is searched for with germanium detectors where source and detector of the decay are identical. For the success of future experiments it is important to increase the mass of the detectors. We report here on the characterization and testing of five prototype detectors manufactured in inverted coaxial (IC) geometry from material enriched to 88% in 76 Ge. IC detectors combine the large mass of the traditional semi-coaxial Ge detectors with the superior resolution and pulse shape discrimination power of point contact detectors which exhibited so far much lower mass. Their performance has been found to be satisfactory both when operated in vacuum cryostat and bare in liquid argon within the Gerda setup. The measured resolutions at the Q -value for double- β decay of 76 Ge ( Q β β  = 2039 keV) are about 2.1 keV full width at half maximum in vacuum cryostat. After 18 months of operation within the ultra-low background environment of the GERmanium Detector Array (Gerda) experiment and an accumulated exposure of 8.5 kg · year, the background index after analysis cuts is measured to be 4 . 9 - 3.4 + 7.3 × 10 - 4 counts / ( keV · kg · year ) around Q β β . This work confirms the feasibility of IC detectors for the next-generation experiment Legend.<br /> (© The Author(s) 2021.)

Details

Language :
English
ISSN :
1434-6044
Volume :
81
Issue :
6
Database :
MEDLINE
Journal :
The European physical journal. C, Particles and fields
Publication Type :
Academic Journal
Accession number :
34720720
Full Text :