Back to Search
Start Over
Total-Body PET Multiparametric Imaging of Cancer Using a Voxelwise Strategy of Compartmental Modeling.
- Source :
-
Journal of nuclear medicine : official publication, Society of Nuclear Medicine [J Nucl Med] 2022 Aug; Vol. 63 (8), pp. 1274-1281. Date of Electronic Publication: 2021 Nov 18. - Publication Year :
- 2022
-
Abstract
- Quantitative dynamic PET with compartmental modeling has the potential to enable multiparametric imaging and more accurate quantification than static PET imaging. Conventional methods for parametric imaging commonly use a single kinetic model for all image voxels and neglect the heterogeneity of physiologic models, which can work well for single-organ parametric imaging but may significantly compromise total-body parametric imaging on a scanner with a long axial field of view. In this paper, we evaluate the necessity of voxelwise compartmental modeling strategies, including time delay correction (TDC) and model selection, for total-body multiparametric imaging. Methods: Ten subjects (5 patients with metastatic cancer and 5 healthy volunteers) were scanned on a total-body PET/CT system after injection of 370 MBq of <superscript>18</superscript> F-FDG. Dynamic data were acquired for 60 min. Total-body parametric imaging was performed using 2 approaches. One was the conventional method that uses a single irreversible 2-tissue-compartment model with and without TDC. The second approach selects the best kinetic model from 3 candidate models for individual voxels. The differences between the 2 approaches were evaluated for parametric imaging of microkinetic parameters and the <superscript>18</superscript> F-FDG net influx rate, K <subscript>i</subscript> Results: TDC had a nonnegligible effect on kinetic quantification of various organs and lesions. The effect was larger in lesions with a higher blood volume. Parametric imaging of K <subscript>i</subscript> with the standard 2-tissue-compartment model introduced vascular-region artifacts, which were overcome by the voxelwise model selection strategy. Conclusion: The time delay and appropriate kinetic model vary in different organs and lesions. Modeling of the time delay of the blood input function and model selection improved total-body multiparametric imaging.<br /> (© 2022 by the Society of Nuclear Medicine and Molecular Imaging.)
Details
- Language :
- English
- ISSN :
- 1535-5667
- Volume :
- 63
- Issue :
- 8
- Database :
- MEDLINE
- Journal :
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
- Publication Type :
- Academic Journal
- Accession number :
- 34795014
- Full Text :
- https://doi.org/10.2967/jnumed.121.262668