[Determination of Endograft Size in Thoracic Endovascular Aortic Repair for Blunt Thoracic Aortic Injury:Report of a Case].

Authors :
Sato H
Sato N
Takesue Y
Kato K
Wakabayashi T
Aoki K
Source :
Kyobu geka. The Japanese journal of thoracic surgery [Kyobu Geka] 2021 Nov; Vol. 74 (12), pp. 1024-1027.
Publication Year :
2021

Abstract

Although the efficacy of thoracic endovascular aortic repair( TEVAR) for blunt thoracic aortic injury (BTAI) has been reported, the determination of the proper endograft size for TEVAR in BTAI cases is yet to be established. The management of BTAI by TEVAR may not be effective if a wrong endograft size is selected, possibly leading to fatal outcomes. In this case report, a hemodynamically unstable patient with BTAI was saved by TEVAR, and the preoperative and postoperative changes in the aortic diameter were compared. In TEVAR for BTAI, the effects of hemodynamic instability should be considered and the appropriate device size should be determined based on blood pressure, pulse, and inferior vena cava diameter.