Back to Search
Start Over
Dosimetric Comparison of Helical Tomotherapy and Intensity-Modulated Proton Therapy in Hippocampus- and Scalp-Sparing Whole Brain Radiotherapy.
- Source :
-
Technology in cancer research & treatment [Technol Cancer Res Treat] 2021 Jan-Dec; Vol. 20, pp. 15330338211060170. - Publication Year :
- 2021
-
Abstract
- Objective: Cognitive decline and alopecia after radiotherapy are challenging problems. We aimed to compare whole brain radiotherapy (WBRT) plans reducing radiation dose to the hippocampus and scalp between helical tomotherapy (HT) and intensity-modulated proton therapy (IMPT). Methods: We conducted a planning study of WBRT for 10 patients. The clinical target volume was defined as the whole brain excluding the hippocampus avoidance (HA) region. The prescribed dose was 30 Gy in 10 fractions to cover 95% of the target. Constraint goals were defined for the target and organs at risk (OAR). Results: Both techniques met the dose constraints for the target and OAR. However, the coverage of the target (dose covering 95% [D95%] and 98% [D98%] of the volume) were better in IMPT than HT (HT vs IMPT: D95%, 29.9 Gy vs 30.0 Gy, P < .001; D98%, 26.7 Gy vs 28.1 Gy, P = .002). The homogeneity and conformity of the target were also better in IMPT than HT (HT vs IMPT: homogeneity index, 1.50 vs 1.28, P < .001; conformity index, 1.30 vs 1.14, P < .001). IMPT reduced the D100% of the hippocampus by 59% (HT vs IMPT: 9.3 Gy vs 3.8 Gy, P < .001) and reduced the Dmean of the hippocampus by 37% (HT vs IMPT: 11.1 Gy vs 7.0 Gy, P < .001) compared with HT. The scalp IMPT reduced the percentage of the volume receiving at least 20 Gy (V20Gy) and V10Gy compared with HT (HT vs IMPT: V20Gy, 56.7% vs 6.6%, P < .001; V10Gy, 90.5% vs 37.1%, P < .001). Conclusion: Both techniques provided acceptable target dose coverage. Especially, IMPT achieved excellent hippocampus- and scalp-sparing. HA-WBRT using IMPT is a promising treatment to prevent cognitive decline and alopecia.
- Subjects :
- Cranial Irradiation adverse effects
Cranial Irradiation standards
Hippocampus diagnostic imaging
Humans
Magnetic Resonance Imaging
Organs at Risk
Proton Therapy adverse effects
Proton Therapy standards
Radiometry
Radiotherapy Planning, Computer-Assisted
Radiotherapy, Image-Guided adverse effects
Radiotherapy, Image-Guided standards
Radiotherapy, Intensity-Modulated adverse effects
Radiotherapy, Intensity-Modulated standards
Cranial Irradiation methods
Hippocampus radiation effects
Proton Therapy methods
Radiotherapy Dosage
Radiotherapy, Image-Guided methods
Radiotherapy, Intensity-Modulated methods
Tomography, Spiral Computed
Subjects
Details
- Language :
- English
- ISSN :
- 1533-0338
- Volume :
- 20
- Database :
- MEDLINE
- Journal :
- Technology in cancer research & treatment
- Publication Type :
- Academic Journal
- Accession number :
- 34806489
- Full Text :
- https://doi.org/10.1177/15330338211060170